Electronic Components Datasheet Search
  English  ▼

X  

1292332 Datasheet(PDF) 4 Page - PHOENIX CONTACT

Part # 1292332
Description  MACX MCR-EX-AP-2REL-2DI-LP-SP - Relay module
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PHOENIX [PHOENIX CONTACT]
Direct Link  http://www.phoenixcontact.com
Logo PHOENIX - PHOENIX CONTACT

1292332 Datasheet(HTML) 4 Page - PHOENIX CONTACT

  1292332 Datasheet HTML 1Page - PHOENIX CONTACT 1292332 Datasheet HTML 2Page - PHOENIX CONTACT 1292332 Datasheet HTML 3Page - PHOENIX CONTACT 1292332 Datasheet HTML 4Page - PHOENIX CONTACT 1292332 Datasheet HTML 5Page - PHOENIX CONTACT 1292332 Datasheet HTML 6Page - PHOENIX CONTACT 1292332 Datasheet HTML 7Page - PHOENIX CONTACT 1292332 Datasheet HTML 8Page - PHOENIX CONTACT 1292332 Datasheet HTML 9Page - PHOENIX CONTACT Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 10 page
background image
Depth NS 35/7,5
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with
EN 60715)
Material specifications
Flammability rating according to UL 94
V0
Housing material
PA 6.6
Environmental and real-life conditions
Ambient conditions
IP20 (Terminal blocks)
Degree of protection
IP30 (Housing)
-20 °C ... 70 °C (Stand-alone device: any mounting position)
-20 °C ... 70 °C (Group assembly: vertical DIN rail without
circulating air)
-20 °C ... 70 °C (Group assembly: vertical DIN rail with circulating
air)
-20 °C ... 70 °C (Group assembly: horizontal DIN rail without
circulating air)
Ambient temperature (operation)
-20 °C ... 70 °C (Group assembly: horizontal DIN rail with
circulating air)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
Permissible humidity (operation)
≤ 95 % (non-condensing)
Approvals
ATEX
 II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3(1) G Ex ec nC [ia Ga] IIC T4 Gc
Identification
 I (M1) [Ex ia Ma] I
IECEx
[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec nC [ia Ga] IIC T4 Gc
Identification
[Ex ia Ma] I
Safety Integrity Level (SIL, IEC 61508)
Identification
2
EMC data
Electromagnetic compatibility
Tested in accordance with the following standards and
regulations: EN 61326-1 For industrial use, NAMUR NE 21
Standards and regulations
Electrical isolation
4-way isolation
MACX MCR-EX-AP-2REL-2DI-LP-SP - Relay module
1292332
https://www.phoenixcontact.com/us/products/1292332
Nov 10, 2025, 12:19AM
Page 4 (10)



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com