29 / 50 page ![]() Data Sheet LTC7899 analog.com Rev. 0 29 of 50 to achieve the higher duty cycle at an effectively lower frequency. Choose a frequency that limits the maximum duty cycle to a value lower than the curve shown in Figure 36. Figure 36. Relationship between Maximum Duty Cycle and Operating Frequency To improve EMI performance, spread spectrum mode can be selected by tying the PLLIN/SPREAD pin to INTVCC. When spread spectrum mode is enabled, the switching frequency modulates within the frequency selected by the FREQ pin and +20%. Spread spectrum mode can be used in any operating mode selected by the MODE pin (burst mode, pulse-skipping mode, or forced continuous mode). A PLL is also available on the LTC7899 to synchronize the internal oscillator to an external clock source connected to the PLLIN/ SPREAD pin. After the PLL locks, BGxx is synchronized to the rising edge of the external clock signal. See the Phase-Locked Loop and Frequency Synchronization section for details. Selecting the Light Load Operating Mode The LTC7899 can be set to enter high efficiency burst mode operation, constant frequency pulse-skipping mode or forced continuous conduction mode at light load currents. To select burst mode operation, tie the MODE pin to VIN–. To select forced continuous operation, tie the MODE pin to INTVCC. To select pulse-skipping mode, tie the MODE pin to INTVCC through a 100k resistor. An internal 100k resistor from the MODE pin to VIN– selects burst mode if the pin is floating. When synchronized to an external clock through the PLLIN/SPREAD pin, the LTC7899 operates in pulse- skipping mode if it is selected, or in forced continuous mode otherwise. Table 5 summarizes the use of the MODE pin to select the light load operating mode. Table 5. Using the MODE Pin to Select Light Load Operating Mode MODE PIN LIGHT LOAD OPERATING MODE MODE WHEN SYNCHRONIZED VIN- or Floating Burst Mode Forced Continuous 100k to INTVCC Pulse-Skipping Pulse-Skipping INTVCC Forced Continuous Forced Continuous In general, the requirements of each application will dictate the appropriate choice for light load operating mode. In burst mode operation, the inductor current is not allowed to reverse. The reverse current comparator turns off the top MOSFET just before the inductor current reaches zero, preventing it from reversing and going negative. Thus, the regulator operates in discontinuous operation. In addition, when the load current is very light, the inductor current will begin bursting at frequencies lower than the switching frequency and enter a low current sleep mode when not switching. As a result, burst mode operation has the highest possible efficiency at light load. 73% AT 2.25MHz FREQUENCY (MHz) 0.1 1 3 65 70 75 80 85 90 95 100 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |