| Electronic Components Datasheet Search |
|
BQ25713 Datasheet(PDF) 32 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ25713 Datasheet(HTML) 32 Page - Texas Instruments |
|
32 / 144 page ![]() the relationship between VBAT and VSYS_MIN() setting referring to Table 7-9. Note when EN_LDO=0b, pre- charge current limit (IPRECHG()) is not effective and provide EC flexibility to program charge current through CHARGE_CURRENT() register. Table 7-3. Default Charging Current Setting VBAT CONDITION CHARGING CURRENT DEFAULT SETTING CHRG_STAT VBAT< VBAT_SHORT IBAT_SHORT 128mA 001 VBAT_SHORT<VBAT< VSYS_MIN() IPRECHG 384mA 010 VSYS_MIN()<VBAT<CHARGE_V OLTAGE() CHARGE_CURRENT() 0A (need host to configure based on battery request) 011 If the charger device is in DPM regulation during charging, the actual charging current will be less than the programmed value. In this case, termination is temporarily disabled and the charging safety timer is counted at half the clock rate, as detailed in Charging Safety Timer section. CHARGE_VOLTAGE() CHARGE_CURRENT() ICHG VSYS_MIN() VBAT_SHORT IPRECHG() ITERM() IBAT_SHORT Battery Voltage Charge Current Trickle Charge Pre-charge Fast-Charge CC CHRG_STAT[2:0] 001 010 011 Taper-Charge CV 100 111 Precharge Timer (2hrs) Safety Timer CHG_TMR[1:0] VRECHG 100 Safety Timer Auto-Recharge CV Charge Termination Done 011 CC Figure 7-4. Typical Li-Ion Battery Charging Profile 7.3.5.3 Charging Termination When autonomous charging is not enabled (EN_AUTO_CHG=0b), the battery charging termination be can be executed when host write CHARGE_CURRENT() register to 0A or set CHRG_INHIBIT=1b based on battery gauge device request. When autonomous charging is enabled (EN_AUTO_CHG=1b), the device terminates a charge cycle when the battery voltage is above the recharge threshold, the converter is operated in the battery constant voltage regulation loop and the current is below the termination current threshold (ITERM() register setting). After the charging cycle is completed, the CHARGE_CURRENT() register is set to 0A to terminate charge and BATFET turns off. The original CHARGE_CURRENT() register setting is logged internally and resumes it to CHARGE_CURRENT() when re-charge condition is detected to restart charging. The converter keeps running to power the system and the BATFET can turn on again if the supplement mode is triggered. BQ25773 SLUSEK7 – SEPTEMBER 2024 www.ti.com 32 Submit Document Feedback Copyright © 2024 Texas Instruments Incorporated Product Folder Links: BQ25773 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |