| Electronic Components Datasheet Search |
|
BQ25713 Datasheet(PDF) 49 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ25713 Datasheet(HTML) 49 Page - Texas Instruments |
|
49 / 144 page ![]() When the charge current is higher than the threshold after 1-μs deglitch time, BATCOC fault is triggered, CHARGE_CURRENT() register is reset back to 0A and BATFET should be turned off accordingly. Status bit FAULT_BATCOC is set and it can only be cleared by host read after 1 second latch time. The above actions are only executed one time after triggered. During this 1 second latch time, non-zero value cannot be written into CHARGE_CURRENT(). In order to recover charging, host need to re-write non-zero CHARGE_CURRENT() register value after it triggers for 1 second. Note this protection only turns off BATFET to disable charge it should not influence BATFET supplement mode turn on state machine. Also the CHRG_OK pin is not influenced under BATCOC fault to avoid unnecessary interference to customer system. 7.3.26.7 Battery Discharge Overcurrent Protection (BATDOC) Under battery only OTG operation, the charger monitors the battery discharge current to provide the battery over current protection (BATDOC) through voltage across SRN and SRP. BATDOC can be enabled by configuring EN_BATDOC=1b. BATDOC threshold is selected either 200% of IDCHG_TH2 or 300% IDCHG_TH2 through BATDOC_VTH bit. There is also fixed low and high clamp for BATDOC threshold. When 200% of IDCHG_TH2 or 300% IDCHG_TH2 corresponding SRN-SRP voltage is below 50 mV , then BATDOC threshold will be low clamped at SRN-SRP=50 mV corresponding current; similarly if 200% of IDCHG_TH2 or 300% IDCHG_TH2 corresponding SRN-SRP voltage is above 180 mV , then BATDOC threshold will be high clamped at SRN- SRP=180 mV corresponding current. When discharge current is higher than the threshold after 250-μs deglitch time, BATDOC fault is triggered, status bit FAULT_BATDOC is set accordingly. Converter shuts down when BATDOC is asserted to disable OTG operation and reduce discharge current. BATFET status is not impacted if need to supplement power to system. BATDOC is not a latch fault, therefore after BATDOC fault is removed, with 250 ms relax time, converter resume switching automatically. But status bit FAULT_BATDOC is only cleared by host read. 7.3.26.8 BATFET Charge Current Clamp Protection under LDO Regulation Mode When charger LDO mode is enabled (EN_LDO=1b) and VBAT voltage falls below VSYS_MIN() during charging, the charger should regulate system output voltage fixed at VSYS_MIN() and battery charging current is regulated by BATFET gate voltage achieving LDO mode operation. Both charger pre-charge and trickle charge status are implemented through this LDO mode operation. Under both pre-charge and trickle charge there are corresponding current limit referring to Battery Charging Profile. Under LDO mode larger VSYS_MIN() minus VBAT delta and larger charge current should generate more thermal dissipation at BATFET which should be properly limited to ensure safe operation. Therefore besides pre-charge and trickle charge current clamp mentioned above, we have additional two levels current clamp to ensure the maximum BATFET dissipation loss below 2W based on the relationship between VBAT and VSYS_MIN() setting referring to Table 7-9. The lower current clamp will dominate the final maximum charge current limit considering IPRECHG() user register upper clamp, battery short trickle charge current clamp (128 mA) and two levels BATFET current clamp below. Table 7-9. BATFET Charge Current Clamp Under LDO Mode NAME VBAT VS VSYS_MIN() MAXIMUM CHARGE CURRENT CLAMP IBATFET_CLAMP1 1V<VSYS_MIN()-VBAT<4V 512 mA (Internal Clamp no impact on IPRECHG() register) IBATFET_CLAMP2 4V<VSYS_MIN()-VBAT 128 mA (Internal Clamp no impact on IPRECHG() register) When charger LDO mode is disabled (EN_LDO=0b), then BATFET will be either fully on or fully off status. When charge is disabled the system voltage is regulated at 5 V (VBAT< 5 V) or VBAT+160 mV (VBAT>5 V); however when charge is enabled then VSYS will be regulated close to VBAT to implement target charging current and VSYS_MIN regulation is not effective. 7.3.26.9 Sleep Comparator Protection Between VBUS and ACP_A (SC_VBUSACP) Under forward mode, it is allowed to add an optional PFET or efuse between VBUS and ACP_A pin which can help shut off converter when there is dead short on Q1_A or Q1_B. Since the turn on delay on PFETs and eFuse is not fixed, sleep comparator protection is employed to ensure PFETs or eFuse is turned on when converter starts up. This sleep comparator is enabled by default (EN_SC_VBUS_ACP=1b) and can be disabled through www.ti.com BQ25773 SLUSEK7 – SEPTEMBER 2024 Copyright © 2024 Texas Instruments Incorporated Submit Document Feedback 49 Product Folder Links: BQ25773 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |