BQ25713 Datasheet(PDF) 39 Page - Texas Instruments

Part # BQ25713
Description  BQ25773 40V, I2C, 2- to 5-Cell, Narrow VDC Quasi Dual Phase Buck-Boost Battery Charge Controller With System Power Monitor and Processor Hot Monitor
PDF  144 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

BQ25713 Datasheet(HTML) 39 Page - Texas Instruments

Back Button BQ25713 Datasheet HTML 35Page - Texas Instruments BQ25713 Datasheet HTML 36Page - Texas Instruments BQ25713 Datasheet HTML 37Page - Texas Instruments BQ25713 Datasheet HTML 38Page - Texas Instruments BQ25713 Datasheet HTML 39Page - Texas Instruments BQ25713 Datasheet HTML 40Page - Texas Instruments BQ25713 Datasheet HTML 41Page - Texas Instruments BQ25713 Datasheet HTML 42Page - Texas Instruments BQ25713 Datasheet HTML 43Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 39 / 144 page
background image
7.3.12 Input Current and Voltage Limit Setup
The actual input current limit being adopted by the device is the lower value of IIN_DPM and ILIM_HIZ pin.
Register IIN_DPM input current limit value will be updated on below scenarios:
• IIN_DPM() will be updated based on IIN_HOST() value except ICO is executed listed below.
• When adapter is removed, IIN_HOST will be reset to 5 A, host can re-write IIN_HOST to new values after
reset under battery only. If the adapter plugs back in and CHRG_OK is pulled up, IIN_HOST will not be reset
again. IIN_DPM follows IIN_HOST value in this scenario.
• When input current optimization (ICO) is executed (EN_ICO_MODE=1b), the charger will automatically detect
the optimized input current limit based on adapter output characteristic. The final IIN_DPM register setting
could be different from IIN_HOST after ICO.
The input current limit function is enabled by default through (EN_IIN_DPM=1b), it can be disabled through
setting EN_IIN_DPM=0b. Status bit IN_IIN_DPM is used to report input current under IIN_DPM() regulation.
The input voltage limit is configurable through VINDPM() register bits. Upon POR, VINDPM() default setting is
A0h (3.2 V). EC host can rewrite to the target value after POR. There is also DETECT_VINDPM bit to DETECT
VINDPM based on VBUS measurement result minus 1.28 V. Write 1b to DETECT_VINDPM bit to start the
process, then converter shuts off to measure VBUS. After VBUS measurement is done, VINDPM() is written with
value VBUS-1.28 V, DETECT_VINDPM bit goes back to 0 and converter starts up again. Status bit IN_VINDPM
is used to report input voltage is under VINDPM regulation.
7.3.13 Battery Cell Configuration
CELL_BATPRES pin is biased with a resistor divider from REGN_A/B to GND. After REGN_A/B ramps up or
CELL_BATPRES pin ramps up, the device detects the battery configuration through CELL_BATPRES pin bias
voltage after 2ms delay time. No external cap is allowed at CELL_BATPRES pin. When CELL_BATPRES pin is
pulled down to GND at the beginning of device start up process, CHARGE_VOLTAGE(), SYSOVP, VSYS_MIN()
and VRECHG() follow battery removal row in the table below.
After device start up when battery is removed, CELL_BATPRES pin should be pulled low through external
MOSFET shown in application diagram. If CELL_BATPRES pin is pulled lower than VCELL_BATPRES_FALL for 1ms
deglitch time, then device disables charge by resetting CHARGE_CURRENT()=000h and EN_AUTO_CHG=0b;
at same time, CHARGE_VOLTAGE(), SYSOVP, VSYS_MIN() and VRECHG() are not changed. When
REGN_A/B voltage rises up or CELL_BATPRES pin is increased higher than VCELL_BATPRES_RISE, the device
should re-read cell configuration again with 2ms delay time: CHARGE_VOLTAGE(), SYSOVP, VSYS_MIN() and
VRECHG() should be re-detected to corresponding cell setting default value if they are not changed by EC
before; if any of CHARGE_VOLTAGE(), SYSOVP, VSYS_MIN() and VRECHG() are changed by EC before this
re-detection then their value should not be influenced by the new detection process anymore. This is needed
to avoid EC writing target value back and forth. Refer to Table 7-6 for CELL_BATPRES pin configuration typical
voltage for swept cell count. Note if device is in learn mode (EN_LEARN=1b). Pulling CELL_BATPRES pin low
clears EN_LEARN bit to 0b and forces device to exit learn mode.
When CELL_BATPRES pin is pulled to ground, battery removal is indicated. Since there is no battery
supplement, the charger can automatically disable IIN_DPM by setting EN_IIN_DPM to 0 to minimize VSYS
voltage drop. This function can be enabled through setting IIN_DPM_AUTO_DISABLE=1b. The host can re-
enable IIN_DPM function later by writing EN_IIN_DPM bit to 1.
Table 7-6. Battery Cell Configuration
CELL COUNT
PIN VOLTAGE w.r.t.
REGN_A/B
CHARGE_VOLTAGE()
SYSOVP
VSYS_MIN
VRECHG
5S
100%
21.000 V
27V
15.4V
500mV
4S
75%
16.800 V
22 V
12.3V
400mV
3S
55%
12.600 V
17 V
9.2V
300mV
2S
40%
8.400 V
12 V
6.6V
200mV
Battery removal
0%
8.400 V
27 V
6.6V
200mV
www.ti.com
BQ25773
SLUSEK7 – SEPTEMBER 2024
Copyright © 2024 Texas Instruments Incorporated
Submit Document Feedback
39
Product Folder Links: BQ25773



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com