| Electronic Components Datasheet Search |
|
MP5026GLRT Datasheet(PDF) 16 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP5026GLRT Datasheet(HTML) 16 Page - Monolithic Power Systems |
|
16 / 24 page ![]() MP5026 – 16V, 20A, 2.8mΩ RDS(ON), HOT-SWAP INTELLI-FUSE SOLUTION MP5026 Rev. 1.0 MonolithicPower.com 16 7/5/2023 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2023 MPS. All Rights Reserved. EN/UV and LOADEN The EN/UV and LOADEN pins control the MP5026 ’s on and off status (see Table 1). During the LOADEN blanking time, EN/UV high is sufficient to turn the MOSFET on. After the LOADEN blanking time expires, EN/UV and LOADEN must be pulled high to turn the device on. Pull EN/UV low to turn the MOSFET off. Cycle the power on EN/UV or VIN to restart the chip once it is latched off. Table 1: EN/UV and LOADEN Blanking Time Is the LOADEN Blanking Time Complete? EN/UV LOADEN Status No 0 0 Off No 0 1 Off No 1 0 On No 1 1 On Yes 0 0 Off Yes 0 1 Off Yes 1 0 Off Yes 1 1 On Note that LOADEN shuts down the power MOSFET after the LOADEN blanking time finishes. However, LOADEN cannot turn the power MOSFET on by cycling the power on LOADEN only (see Figure 3). Power MOSFET LOADEN ENTM EN/UV Off On 1.21V t Figure 3: EN/UV and LOADEN Timing Diagram If VIN and VCC are ready when the part is enabled, the internal 24 μA current source charges the power MOSFET ’s gate. It takes about 1ms to charge VGS to its threshold. Then VOUT rises based on the SS-controlled slew rate. LOADEN Blanking Time LOADEN has a configurable blanking time that prevents the pin from de-asserting during the blanking time (see Figure 4). LOADEN Blanking Time EN/UV LOADEN ENTM 1.21V VOUT VIN Figure 4: LOADEN Blanking Time Since all fault functionalities are operative during start-up, the power MOSFET shuts down if a fault is detected. However, LOADEN going low during this blanking time does not turn the MOSFET off. At the end of the blanking time, LOADEN operates normally. The LOADEN blanking time (tLDNB) can be set by a capacitor placed at the ENTM pin. The LOADEN blanking time capacitor (CENTM) can be calculated with Equation (3): = ENTM LDNB 1.1 C( μF) t (s) 1.24 (3) For example, a 1 μF capacitor requires a 1.13s tLDNB. If LOADEN is not used, connect ENTM to GND. Over-Current Protection (OCP) The MP5026 provides a constant current limit that can be configured via an external resistor. The Intelli-Fuse over-current limit (ILIMIT) is a function of the ISET resistor (RISET). ILIMIT can be calculated with Equation (4): 3 LIMIT ISET 0.3V I (A) = 10 R (k Ω) (4) If VOUT is below the larger value between VIN - 0.5V and 80% of VIN, then the MP5026 enters start-up. To protect the device from overheating during start-up, ILIMIT has a 20A internal current limit clamp. The actual start-up current limit (ILIMIT_SS) is the smaller value between ILIMIT and 20A (see Figure 5 on page 17). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |