| Electronic Components Datasheet Search |
|
DSP56309 Datasheet(PDF) 10 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56309 Datasheet(HTML) 10 Page - Freescale Semiconductor, Inc |
|
10 / 108 page ![]() DSP56309 Technical Data, Rev. 7 1-6 Freescale Semiconductor Signals/Connections BG Input Ignored Input Bus Grant—Asserted by an external bus arbitration circuit when the DSP56309 becomes the next bus master. When BG is asserted, the DSP56309 must wait until BB is deasserted before taking bus mastership. When BG is deasserted, bus mastership is typically given up at the end of the current bus cycle. This may occur in the middle of an instruction that requires more than one external bus cycle for execution. The default operation of this bit requires a setup and hold time as specified in Table 2- 14. An alternate mode can be invoked: set the asynchronous bus arbitration enable (ABE) bit (Bit 13) in the Operating Mode Register. When this bit is set, BG and BB are synchronized internally. This eliminates the respective setup and hold time requirements but adds a required delay between the deassertion of an initial BG input and the assertion of a subsequent BG input. BB Input/ Output Ignored Input Bus Busy—Indicates that the bus is active. Only after BB is deasserted can the pending bus master become the bus master (and then assert the signal again). The bus master may keep BB asserted after ceasing bus activity regardless of whether BR is asserted or deasserted. Called “bus parking,” this allows the current bus master to reuse the bus without rearbitration until another device requires the bus. BB is deasserted by an “active pull-up” method (that is, BB is driven high and then released and held high by an external pull-up resistor). The default operation of this signal requires a setup and hold time as specified in Table 2-14. An alternative mode can be invoked by setting the ABE bit (Bit 13) in the Operating Mode Register. When this bit is set, BG and BB are synchronized internally. See BG for additional information. Note: BB requires an external pull-up resistor. CAS Output Tri-stated Column Address Strobe—When the DSP is the bus master, CAS is an active-low output used by DRAM to strobe the column address. Otherwise, if the Bus Mastership Enable (BME) bit in the DRAM control register is cleared, the signal is tri-stated. BCLK Output Tri-stated Bus Clock When the DSP is the bus master, BCLK is active when the Operating Mode Register Address Trace Enable bit is set. When BCLK is active and synchronized to CLKOUT by the internal PLL, BCLK precedes CLKOUT by one-fourth of a clock cycle. BCLK Output Tri-stated Bus Clock Not When the DSP is the bus master, BCLK is the inverse of the BCLK signal. Otherwise, the signal is tri-stated. Table 1-8. External Bus Control Signals (Continued) Signal Name Type State During Reset, Stop, or Wait Signal Description |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |