  HV57009 Datasheet HTML 1Page - Supertex, Inc HV57009 Datasheet HTML 2Page - Supertex, Inc HV57009 Datasheet HTML 3Page - Supertex, Inc HV57009 Datasheet HTML 4Page - Supertex, Inc HV57009 Datasheet HTML 5Page - Supertex, Inc HV57009 Datasheet HTML 6Page - Supertex, Inc HV57009 Datasheet HTML 7Page - Supertex, Inc  
Zoom Inzoom in Zoom Outzoom out
 7 / 7 page
background image
7
HV57009
IOUT
HVOUT
VDD
VREF
IREF
REXT
+IN
-IN
RD*
10K
CD*
390pF
HV570
Logic
To other
outputs
- +
0.1µF
VBP
VSS
VREF
IOUT
HVOUT
VDD
0.1µF
VBP
IREF
REXT
+IN
-IN
RD*
10K
CD*
390pF
HV570
Logic
To other
outputs
-+
VSS
Since I
OUT
= I
REF
=
Therefore, if I
OUT = 2mA and VREF = -5V → REXT = 2.5KΩ.
If I
OUT = 1mA and REXT = 1KΩ → VREF = -1V.
If R
EXT >10KΩ,
add series network R
D and CD to ground for
stability as shown.
This control method behaves linearly as long as the operational
amplifier is not saturated. However, it requires a negative power
source and needs to provide a current I
REF = IOUT for each HV570
chip being controlled.
If HV
OUT ≥ +1V, the HVOUT cascode may no longer operate as a
perfect current source, and the output current will diminish. This
effect depends on the magnitude of the output current.
Given I
OUT and VREF, the REXT can be calculated
by using:
R
EXT =
V
REF
=
V
REF
I
REF
I
OUT
The intersection of a set of I
OUT and VREF values can be located
in the graph shown below. The value picked for R
EXT must always
be in the shaded area for linear operation. This control method
has the advantage that V
REF is positive, and draws only leakage
current. If R
EXT > 10K, add series network RD and CD to ground
for stability as shown.
Note: Lower reference current I
REF, results in higher distortion,
∆I
CS, on the output.
*Required if R
EXT > 10K or REXT is replaced by a constant
current source.
Typical Current
Programming Circuits
Figure 8b: Positive Control
Figure 8a: Negative Control
V
REF
R
EXT
12
3
4
5
3
4
5
6
7
8
2
1
0
VREF (V)
100
250
500
REXT = 1K
5K
2K
1235 Bordeaux Drive, Sunnyvale, CA 94089
TEL: (408) 744-0100 • FAX: (408) 222-4895
www.supertex.com
03/12/02
©2001 Supertex Inc. All rights reserved. Unauthorized use or reproduction prohibited.



Html Pages

1 2 3 4 5 6 7


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com