SIM765170 Datasheet(PDF) 4 Page - celduc-relais

Part # SIM765170
Description  AC Semiconductor Contactor pitch 45mm compact size and DIN rail mounting.
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  CELDUC [celduc-relais]
Direct Link  http://www.celduc-relais.com/uk/index.asp
Logo CELDUC - celduc-relais

SIM765170 Datasheet(HTML) 4 Page - celduc-relais

  SIM765170 Datasheet HTML 1Page - celduc-relais SIM765170 Datasheet HTML 2Page - celduc-relais SIM765170 Datasheet HTML 3Page - celduc-relais SIM765170 Datasheet HTML 4Page - celduc-relais  
Zoom Inzoom in Zoom Outzoom out
 4 / 4 page
background image
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21
Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
www.celduc.com
celduc
Load
Charge
Fuse
Fusible
L1
T1
1 ~
control
A2
A1
N
+
-
Mounting
Ø
Warning : only in vertical position. The user should protect heat sensitive materials as
well as persons against any contacts with the heatsink. For non vertical mounting , the load
current must be 50% lower than the rated one . For a good cooling, the SSR needs an air
convection. Less convection air produces an abnormal heating. Keep a distance between
the upper SSR and the lower SSR. In case of no space between two SSR ( zero space
between two SSRs) , please reduce the load current. For further details refer to below :
Ø Derating current with no space between SSRs
AC-51 nominal currents are given with a space of 22,5mm between each SSR, for a
permanent current during a minimum time of 8 hours in air calm according to IEC60947-4-3.
In case of non permanent currents or in case of SSRs are mounted with no space, you must
check the heatsink temperature never exceed 90°C. When the SSRs are mounted side to
side ( no space between each relay) a derating current of 25% must be take into account.
A forced cooling ( fan inside the cabinet) improves significantly the thermal performances.
Typical application : LOADS
SIM765 product is designed mainly for AC-53 motor load. AC-51 resistive loads are
also given . For other loads, check the inrush current at turn ON and possible overvoltages
at turn OFF or consult us :
* AC-55b : Incandescent lamps : Inrush current is generally 10 times In during few 10ms.
So limit the nominal current at about 15A.The SIM765 can be used for phase angle control-
ler with an adapted control.
* AC-55a : Electric discharge lamp : These loads often have overcurrent at turn ON and
overvoltage at turn OFF, so we advise to use 400VAC SSR on 230VAC mains.
* AC-56a : Transformers loads : Very high inrush current up to 100 times In . This model can
be used for this application provided the maximum current are respected.
* AC-56b : Capacitors loads : No adapted to this type of load. See zero cross models.
Protection :
To protect the SSR against a short-circuit of the load , use a fuse with a I2t value = 1/2 I2t
value specified page 2. A test has been made with FERRAZ fuse ( see page 2).
It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application
note ( SSR protection) and use a SSR with high I2t value (5000A2s minimum).
EMC :
Ø
Immunity :
We give in our data-sheets, the immunity level of our SSRs according to the main
standards for this type of products : EN61000-4-4 &5. You can see the high immunity level
in comparison with the products on the market.
Ø
Emission:
SSRs are complex devices which must be interconnected with other equipment
(loads, cables,etc.) to form a system. Because the other equipment or the interconnections
may not be under the control of celduc, it shall be the responsibility of the system integrator
to ensure that systems containing SSRs comply with the requirements of any rules and
regulations applicable at the system level.
Consult celduc laboratory which can make some tests in your application.
page 4 / 4GB
S/CLP/SIM765170/B/21/04/2004
celpac®
Connections .
Ø
For
the output terminals, the wire cross sections must
be adapted to the load current and to the overcurrent protection
device characteristics. The relay rated voltage must be adapted
to the mains rated voltage.
Ø
celpac use screw clamp connections.
80mm
vertical
position
wires
(mm2)
torques
screwdriver
control
1 x(0,75-->2,5)
L = 6mm
0,4N.m
(0,6N.m max)
3,5x0,5mm
Power
1x(1,5-->16) 1 x(1,5-->10)
L = 10mm
1,2N.m
(1,8N.m max)
Pozidriv2/
0,8x5,5 (1x6)
screwdriver
L
L



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com