22 / 36 page ![]() CS5530 22 DS742F2 2.4.4 Performing Calibrations To perform a calibration, the user must send a com- mand byte with its MSB=1, and the appropriate calibration bits (CC2-CC0) set to choose the type of calibration to be performed. The calibration will be performed using the filter rate, and siganl span (unipolar or bipolar) as set in the configuration reg- ister. The length of time it takes to do a calibration is slightly less than the amount of time it takes to do a single conversion (see Table 1 for single conver- sion timing). Offset calibration takes 608 clock cy- cles less than a single conversion when FRS = 0, and 729 clock cycles less when FRS = 1. Gain cal- ibration takes 128 clock cycles less than a single conversion when FRS = 0, and 153 clock cycles less when FRS = 1. Once a calibration cycle is complete, SDO falls and the results are automatically stored in either the gain or offset register. SDO will remain low until the next command word is begun. If additional cal- ibrations are performed while referencing the same calibration registers, the last calibration results will replace the effects from the previous calibration. Only one calibration is performed with each com- mand byte. 2.4.5 System Calibration For the system calibration functions, the user must supply the converter input calibration signals which represent ground and full-scale. When a system off- set calibration is performed, a ground referenced sig- nal must be applied to the converter. Figure 10 illustrates system offset calibration. As shown in Figure 11, the user must input a signal representing the positive full-scale point to perform a system gain calibration. In either case, the cali- bration signals must be within the specified calibra- tion limits for each specific calibration step (refer to the System Calibration Specifications). 2.4.6 Calibration Tips Calibration steps are performed at the output word rate selected by the WR3-WR0 bits of the configu- ration register. To minimize the effects of peak-to- peak noise on the accuracy of calibration the con- verter should be calibrated using the slowest word rate that is acceptable. It is recommended that word rates of 240 Sps and higher not be used for calibration.) To minimize digital noise near the de- vice, the user should wait for each calibration step to be completed before reading or writing to the se- rial port. Reading the calibration registers and aver- aging multiple calibrations together can produce a more accurate calibration result. Note that access- ing the ADC’s serial port before a calibration has finished may result in the loss of synchronization between the microcontroller and the ADC, and may prematurely halt the calibration cycle. Figure 10. System Calibration of Offset Figure 11. System Calibration of Gain |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |