2 / 16 page ![]() 2 Test Signal Frequency 75 kHz to 30 MHz, 100 Hz solution Frequency accuracy ±0.01% Signal modes Normal—Program selected voltage or current at the measurement terminals when they are opened or shorted, respectively Constant—Maintains selected voltage or current at the device under test (DUT) independent of changes in the device’s impedance. Signal level The following test signal level accuracy is specified for an ambient temperature range of 23 °C ± 5 °C and the test cable length is 0 m. Mode Range Setting accuracy Voltage Normal 5 m Vrms to 2 Vrms ±{(8 + 0.4 fm)% + 1 m Vrms} Constant 1 10 mVrms to 1 Vrms ±{(6 + 0.2 fm)% + 1 m Vrms} Current Normal 200 µArms to 20 mArms ±{(8 + 1 fm)% + 40 µArms} Constant 1 100 µArms to 20 mArms ±{(6 + 0.2 fm)% + 40 µArms} 1. When the ALC function is set to ON For the temperature range of 0 °C to 55 °C, multi- ply the temperature induced setting error listed in Figure 1-5 to the test signal setting accuracy. When test cable length is 1 m or 2 m, add the following error due to test cable length. 0.2 fm L [%] where: fm = Test frequency [MHz] L = Test cable length [m] Output impedance The following output impedance is specified for the test cable length of 0 m: ( 2 ) (25 + 0.5 fm) Ω ± 10 + 3 fm % where: fm = Test frequency [MHz] Test signal level monitor The following test signal level monitor accuracy is specified for an ambient temperature range of 23 °C ± 5 °C and the test cable length is 0 m. Mode Range Monitor accuracy Voltage 0.01 mVrms – 2.000 Vrms Current 0.001 µArms – 20.00 mArms For the temperature range of 0 °C to 55 °C, multi- ply the temperature induced setting error listed in Figure 1-5. When test cable length is 1 m or 2 m, add the following error due to test cable length. Smon 0.2 fm L [V ] where: fm = Test frequency [MHz] L = Test cable length [m] Smon = Readout value of test signal level Sset = Setting value of test signal level For example, Test frequency: 1 MHz Test signal level: 1 Vrms Monitor readout value: 500 mVrms Cable length: 1 m Ambient temperature: 25 °C Smon Sset [V ] 4 + 0.2 fm 100 500 {} ± + |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |