13 / 29 page ![]() ADM1024 http://onsemi.com 13 positive and negative temperatures can be measured, the temperature data is stored in twos complement format, as shown in Table 4. Theoretically, the temperature sensor and ADC can measure temperatures from −128 °C to +127°C with a resolution of 1 °C, although temperatures below −40 °C and above +125°C are outside the operating temperature range of the device. External Temperature Measurement The ADM1024 can measure the temperature of two external diode sensors or diode−connected transistors, connected to Pins 13 and 14 or 17 and 18. Pins 13 and 14 are a dedicated temperature input channel. Pins 17 and 18 can be configured to measure a diode sensor by setting Bit 2 of the Channel Mode Register to 1. The forward voltage of a diode or diode−connected transistor, operated at a constant current, exhibits a negative temperature coefficient of about –2 mV/ °C. Unfortunately, the absolute value of VBE varies from device to device, and individual calibration is required to null this out, so the technique is unsuitable for mass production. The technique used in the ADM1024 is to measure the change in VBE when the device is operated at two different currents. This is given by: (eq. 5) DVbe + KT q ln(N) where: K is Boltzmann’s constant. q is the charge on the carrier. T is the absolute temperature in Kelvins. N is the ratio of the two currents. Figure 17 shows the input signal conditioning used to measure the output of an external temperature sensor. This figure shows the external sensor as a substrate transistor provided for temperature monitoring on some microprocessors, but it could equally well be a discrete transistor. I D+ LPF N y I IBIAS VDD BIAS DIODE D– LOW−PASS FILTER fC = 65kHz VOUT+ VOUT– TO ADC REMOTE SENSING TRANSISTOR Figure 17. Signal Conditioning for External Diode Temperature Sensors If a discrete transistor is used, the collector will not be grounded and should be linked to the base. If a PNP transistor is used, the base is connected to the D− input and the emitter to the D+ input. If an NPN transistor is used, the emitter is connected to the D− input and the base to the D+ input. To prevent ground noise from interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the D− input. As the sensor is operating in a noisy environment, C1 is provided as a noise filter. See the Layout Considerations section for more information on C1. To measure DVBE, the sensor is switched between operating currents of I and N × I. The resulting waveform is passed through a 65 kHz low−pass filter to remove noise, then to a chopper−stabilized amplifier that performs the functions of amplification and rectification of the waveform to produce a dc voltage proportional to DVBE. This voltage is measured by the ADC to give a temperature output in 8−bit twos complement format. To further reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement cycles. An external temperature measurement takes nominally 9.6 ms. The results of external temperature measurements are stored in 8−bit, twos complement format, as illustrated in Table 4. Table 4. Temperature Data Format Temperature Digital Output −128°C 1000 0000 −125°C 1000 0011 −100°C 1001 1100 −75°C 1011 0101 −50°C 1100 1110 −25°C 1110 0111 0°C 0000 0000 +0.5°C 0000 0000 +10°C 0000 1010 +25°C 0001 1001 +50°C 0011 0010 +75°C 0100 1011 +100°C 0110 0100 +125°C 0111 1101 +127°C 0111 1111 Layout Considerations Digital boards can be electrically noisy environments, and care must be taken to protect the analog inputs from noise, particularly when measuring the very small voltages from a remote diode sensor. The following precautions should be taken: 1. Place the ADM1024 as close as possible to the remote sensing diode. Provided that the worst noise sources such as clock generators, data/address buses, and CRTs are avoided, this distance can be 4 inches to 8 inches. 2. Route the D+ and D− tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |