21 / 29 page ![]() ADM1024 http://onsemi.com 21 Once the interrupt has been cleared, it will not be reasserted even if the temperature remains above the high limit(s). However, INT will be reasserted if: The temperature falls below the low limit for the sensor; or: The high limit(s) is/are reprogrammed to a new value, and the temperature then rises above the new high limit on the next monitoring cycle; or: The THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2; or: An interrupt is generated by another source. Similarly, should the temperature measured by a sensor start off within limits then fall below the low limit, INT will be asserted. Once cleared, it will not be reasserted unless: The temperature rises above the high limit; or: The low limit(s) is/are reprogrammed, and the temperature then falls below the new low limit; or: The THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2; or: An interrupt is generated by another source. THERM Input/Output The Thermal Management Input/Output (THERM) is a logic input/output with an internal, 100 k W pullup resistor, that provides a separate output for temperature interrupts only. It is enabled by setting Bit 2 of Configuration Register 1. The THERM output has two operating modes that can be programmed by Bit 3 of Configuration Register 2 (address 4Ah). With this bit set to the default value of 0, the THERM output operates in “Default” interrupt mode. With this bit set to 1, the THERM output operates in “ACPI” mode. Thermal interrupts can still be generated at the INT output while THERM is enabled, but if these are not required they can be masked by writing a 1 to Bit 0 of Configuration Register 2 (address 4Ah). The THERM pin can also function as a logic input for an external sensor, for example, a temperature sensor such as the ADM22105 used in Figure 35. If THERM is taken low by an external source, the analog output will be forced to FFh to switch a controlled fan to maximum speed. This also generates an INT output as previously described. Default Mode In Default mode, the THERM output operates like a thermostat with hysteresis. THERM will go low and Bit 5 of Interrupt Status Register 2 will be set, if the temperature measured by any of the sensors exceeds the high limit programmed for that sensor. It will remain asserted until reset by reading Interrupt Status Register 2, by setting Bit 6 of Configuration Register 1, or when the temperature falls below the low limit programmed for that sensor. Figure 34. INT or THERM Output in Default Mode TEMP TEMP HIGH LIMIT TEMP LOW LIMIT THERM CLEARED BY READ OR THERM CLEAR PROGRAMMED VALUE ANALOG OUTPUT CLEARED BY TEMP FALLING BELOW LOW LIMIT 0xFF EXT THERM INPUT If THERM is cleared by reading the status register, it will be reasserted after the next temperature reading and comparison if it remains above the high limit. If THERM is cleared by setting Bit 6 of Configuration Register 1, it cannot be reasserted until this bit is cleared. THERM will also be asserted if one of the hardware temperature limits at addresses 13h, 14h, 17h, or 18h is exceeded for three consecutive measurements. When this happens, the analog output will be forced to FFh to boost a controlled cooling fan to full speed. Reading Status Register 1 will not clear THERM in this case, because errors caused by exceeding the hardware temperature limits are stored in a separate register that is not cleared by reading the status register. In this case, THERM can only be cleared by setting Bit 0 of Configuration Register 2. THERM will be cleared automatically if the temperature falls at least 5 degrees below the limit for three consecutive measurements. ACPI Mode In ACPI mode, THERM responds only to the hardware temperature limits at addresses 13h, 14h, 17h, and 18h, not to the software−programmed limits. Figure 35. THERM Output in ACPI Mode TEMP HARDWARE TRIP POINT THERM ANALOG OUTPUT PROGRAMMED VALUE 55 0xFF 0xFF THERM EXT INPUT THERM will go low if either the internal or external hardware temperature limit is exceeded for three consecutive measurements. It will remain low until the temperature falls at least 5 degrees below the limit for three consecutive measurements. While THERM is low, the analog output will go to FFh to boost a controlled fan to full speed. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |