ADM1024 Datasheet(PDF) 21 Page - ON Semiconductor

Part # ADM1024
Description  System Hardware Monitor with Remote Diode Thermal Sensing
PDF  29 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ONSEMI [ON Semiconductor]
Direct Link  http://www.onsemi.com
Logo ONSEMI - ON Semiconductor

ADM1024 Datasheet(HTML) 21 Page - ON Semiconductor

Back Button ADM1024 Datasheet HTML 17Page - ON Semiconductor ADM1024 Datasheet HTML 18Page - ON Semiconductor ADM1024 Datasheet HTML 19Page - ON Semiconductor ADM1024 Datasheet HTML 20Page - ON Semiconductor ADM1024 Datasheet HTML 21Page - ON Semiconductor ADM1024 Datasheet HTML 22Page - ON Semiconductor ADM1024 Datasheet HTML 23Page - ON Semiconductor ADM1024 Datasheet HTML 24Page - ON Semiconductor ADM1024 Datasheet HTML 25Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 29 page
background image
ADM1024
http://onsemi.com
21
Once the interrupt has been cleared, it will not be
reasserted even if the temperature remains above the high
limit(s). However, INT will be reasserted if:
The temperature falls below the low limit for the sensor;
or:
The high limit(s) is/are reprogrammed to a new value, and
the temperature then rises above the new high limit on the
next monitoring cycle;
or:
The THERM pin is pulled low externally, which sets Bit 5
of Interrupt Status Register 2;
or:
An interrupt is generated by another source.
Similarly, should the temperature measured by a sensor
start off within limits then fall below the low limit, INT will
be asserted. Once cleared, it will not be reasserted unless:
The temperature rises above the high limit;
or:
The low limit(s) is/are reprogrammed, and the temperature
then falls below the new low limit;
or:
The THERM pin is pulled low externally, which sets Bit 5
of Interrupt Status Register 2;
or:
An interrupt is generated by another source.
THERM Input/Output
The Thermal Management Input/Output (THERM) is a
logic input/output with an internal, 100 k
W pullup resistor,
that provides a separate output for temperature interrupts
only. It is enabled by setting Bit 2 of Configuration Register 1.
The THERM output has two operating modes that can be
programmed by Bit 3 of Configuration Register 2 (address
4Ah). With this bit set to the default value of 0, the THERM
output operates in “Default” interrupt mode. With this bit set
to 1, the THERM output operates in “ACPI” mode.
Thermal interrupts can still be generated at the INT output
while THERM is enabled, but if these are not required they can
be masked by writing a 1 to Bit 0 of Configuration Register 2
(address 4Ah). The THERM pin can also function as a logic
input for an external sensor, for example, a temperature sensor
such as the ADM22105 used in Figure 35. If THERM is taken
low by an external source, the analog output will be forced to
FFh to switch a controlled fan to maximum speed. This also
generates an INT output as previously described.
Default Mode
In Default mode, the THERM output operates like a
thermostat with hysteresis. THERM will go low and Bit 5 of
Interrupt Status Register 2 will be set, if the temperature
measured by any of the sensors exceeds the high limit
programmed for that sensor. It will remain asserted until
reset by reading Interrupt Status Register 2, by setting Bit 6
of Configuration Register 1, or when the temperature falls
below the low limit programmed for that sensor.
Figure 34. INT or THERM Output in Default Mode
TEMP
TEMP
HIGH LIMIT
TEMP
LOW LIMIT
THERM
CLEARED BY
READ OR
THERM CLEAR
PROGRAMMED
VALUE
ANALOG
OUTPUT
CLEARED BY
TEMP FALLING
BELOW LOW
LIMIT
0xFF
EXT
THERM
INPUT
If THERM is cleared by reading the status register, it will
be reasserted after the next temperature reading and
comparison if it remains above the high limit.
If THERM is cleared by setting Bit 6 of Configuration
Register 1, it cannot be reasserted until this bit is cleared.
THERM will also be asserted if one of the hardware
temperature limits at addresses 13h, 14h, 17h, or 18h is
exceeded for three consecutive measurements. When this
happens, the analog output will be forced to FFh to boost a
controlled cooling fan to full speed.
Reading Status Register 1 will not clear THERM in this
case, because errors caused by exceeding the hardware
temperature limits are stored in a separate register that is not
cleared by reading the status register. In this case, THERM
can only be cleared by setting Bit 0 of Configuration
Register 2.
THERM will be cleared automatically if the temperature
falls at least 5 degrees below the limit for three consecutive
measurements.
ACPI Mode
In ACPI mode, THERM responds only to the hardware
temperature limits at addresses 13h, 14h, 17h, and 18h, not
to the software−programmed limits.
Figure 35. THERM Output in ACPI Mode
TEMP
HARDWARE
TRIP POINT
THERM
ANALOG
OUTPUT
PROGRAMMED
VALUE
55
0xFF
0xFF
THERM
EXT
INPUT
THERM will go low if either the internal or external
hardware temperature limit is exceeded for three
consecutive measurements. It will remain low until the
temperature falls at least 5 degrees below the limit for three
consecutive measurements. While THERM is low, the
analog output will go to FFh to boost a controlled fan to full
speed.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com