| Electronic Components Datasheet Search |
|
ADP4100 Datasheet(PDF) 12 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADP4100 Datasheet(HTML) 12 Page - ON Semiconductor |
|
12 / 22 page ![]() ADP4100 http://onsemi.com 12 through a resistor, RB, to the regulation point, usually the remote sense pin of the microprocessor. FBRTN is connected directly to the remote sense ground point. The internal VID DAC and precision reference are referenced to FBRTN, which has a minimal current of 100 mA to allow accurate remote sensing. The internal error amplifier compares the output of the DAC to the FB pin to regulate the output voltage. Output Current Sensing The ADP4100 provides a dedicated Current−Sense Amplifier (CSA) to monitor the total output current for proper voltage positioning vs. load current, for the IMON output and for current−limit detection. Sensing the load current at the output gives the total real time current being delivered to the load, which is an inherently more accurate method than peak current detection or sampling the current across a sense element such as the low−side MOSFET. This amplifier can be configured several ways, depending on the objectives of the system, as follows: • Output inductor DCR sensing without a thermistor for lowest cost. • Output inductor DCR sensing with a thermistor for improved accuracy with tracking of inductor temperature. • Sense resistors for highest accuracy measurements. The positive input of the CSA is connected to the CSREF pin, which is connected to the average output voltage. The inputs to the amplifier are summed together through resistors from the sensing element, such as the switch node side of the output inductors, to the inverting input CSSUM. The feedback resistor between CSCOMP and CSSUM sets the gain of the amplifier and a filter capacitor is placed in parallel with this resistor. The gain of the amplifier is programmable by adjusting the feedback resistor. This difference signal is used internally to offset the VID DAC for voltage positioning. The difference between CSREF and CSCOMP is used as a differential input for the current−limit comparator. To provide the best accuracy for sensing current, the CSA is designed to have a low offset input voltage. Also, the sensing gain is determined by external resistors to make it extremely accurate. Current−Limit Setpoint The current limit threshold on the ADP4100 is programmed by a resistor between the ILIMFS pin and the CSCOMP pin. The ILIMFS current, IILIMFS, is compared with an internal current reference of 22 mA. If IILIMFS exceeds 22 mA then the output current has exceeded the limit and the current limit protection is tripped. IILIMFS + VILIMFS * VCSCOMP RILIMFS (eq. 2) Where: VILIMFS = VCSREF IILIMFS + VCSREF * VCSCOMP RILIMFS VCSREF * VCSCOMP + RCS RPH RL ILOAD (eq. 3) Where: RL = DCR of the Inductor Assuming that: RCS RPH RL + 1mW (eq. 4) i.e. the external circuit is set up for a 1 m W Loadline then the RILIMFS is calculated as follows: IILIMFS + 1mW ILOAD RLIMITS (eq. 5) Assuming we want a current limit of 150 A that means that ILIMFS must equal 22 mA at that load. 22 mA + 1mW 150 A RLIMITFS (eq. 6) Solving this equation for RLIMITFS we get 6.8 kW. Closest 1% resistor is 6.81 k W. Current−Limit, Short−Circuit and Latchoff Protection If the current limit is reached and TD5 has completed, an internal latchoff delay time will start, and the controller will shut down if the fault is not removed. This delay is four times longer than the delay time during the startup sequence. The current limit delay time only starts after the TD5 has completed. If there is a current limit during startup, the ADP4100 will go through TD1 to TD5, and then start the latchoff time. Because the controller continues to cycle the phases during the latchoff delay time, if the short is removed before the timer is complete, the controller can return to normal operation. The latchoff function can be reset by either removing and reapplying the supply voltage to the ADP4100, or by toggling the EN pin low for a short time. During startup when the output voltage is below 200 mV, a secondary current limit is active. This is necessary because the voltage swing of CSCOMP cannot go below ground. This secondary current limit limits the internal COMP voltage to the PWM comparators to 1.5 V. This limits the voltage drop across the low−side MOSFETs through the current balance circuitry. Typical overcurrent latchoff waveforms are shown in Figure 9). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |