| Electronic Components Datasheet Search |
|
ADP4100 Datasheet(PDF) 15 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADP4100 Datasheet(HTML) 15 Page - ON Semiconductor |
|
15 / 22 page ![]() ADP4100 http://onsemi.com 15 This ramp voltage should be set to at least 0.5 V for noise immunity reasons. If it is less than 0.5 V then decrease the ramp resistor. Dynamic VID The ADP4100 has the ability to respond to dynamically changing VID inputs while the controller is running. This allows the output voltage to change while the supply is running and supplying current to the load. This is commonly referred to as Dynamic VID (DVID). A DVID can occur under either light or heavy load conditions. The processor signals the controller by changing the VID inputs in a single or multiple steps from the start code to the finish code. This change can be positive or negative. When a VID bit changes state, the ADP4100 detects the change and ignores the DAC inputs for a minimum of 200 ns. This time prevents a false code due to logic skew while the VID inputs are changing. Additionally, the first VID change initiates the PWRGD and CROWBAR blanking functions for a minimum of 100 ms to prevent a false PWRGD or CROWBAR event. Each VID change resets the internal timer. If a VID off code is detected the ADP4100 will wait for 5 msec to ensure that the code is correct before initiating a shutdown of the controller. Enhanced Transients Mode The ADP4100 incorporates enhanced transient response for both load step up and load release. For load step up it senses the output of the error amp to determine if a load step up has occurred and then sequences on the appropriate number of phases to ramp up the output current. For load release, it also senses the output of the error amp and uses the load release information to trigger the TRDET pin, which is then used to adjust the error amp feedback for optimal positioning. This is especially important during high frequency load steps. Additional information is used during load transients to ensure proper sequencing and balancing of phases during high frequency load steps as well as minimizing the stress on components such as the input filter and MOSFETs. TRDET and Phase Shuffling The ADP4100 senses the error amp output and triggers the TRDET pin when a load release takes place. The TRDET circuit, as shown in Figure 2, adjusts the feedback for optimal positioning especially during high frequency load steps. TRDET is also used to trigger phase shuffling. If repeated transients take place at the switching frequency then its possible for one phase to carry most of the currrent. To prevent this from happening the ADP4100 will shuffle the phases whenever a load release happens, i.e. it will randomize the phase sequence. Reference Current The IREF pin is used to set an internal current reference. This reference current sets IFB and ITTSENSE. A resistor to ground programs the current based on the 1.8 V output. (eq. 19) IREF + 1.8 V RIREF Typically, RIREF is set to 121 kW to program IREF = 15 mA. The following currents are then equal to: (eq. 20) IFB + IREF + 15 mA ITTSENSE + −8(IIREF) + −120 mA Power Good Monitoring The power good comparator monitors the output voltage via the CSREF pin. The PWRGD pin is an open−drain output whose high level (when connected to a pullup resistor) indicates that the output voltage is within the nominal limits specified in the specifications above based on the VID voltage setting. PWRGD goes low if the output voltage is outside of this specified range, if the VID DAC inputs are in no CPU mode, or whenever the EN pin is pulled low. PWRGD is blanked during a DVID event for a period of 100 ms to prevent false signals during the time the output is charging. The PWRGD circuitry also incorporates an initial turn−on delay time (TD5). Prior to the SS voltage reaching the programmed VID DAC voltage and the PWRGD masking time finishing, the PWRGD pin is held low. Once the SS circuit reaches the programmed DAC voltage, the internal timer operates. The range for the PWRGD comparator is +300 mV and −500 mV. Power State Indicator The PSI pin is an input used to determine the operating state of the load. If this input is pulled low, the load is in a low power state and the controller asserts the ODN pin low, which can be used to disable phases and maintain better efficiency at lighter loads. The sequencing into and out of low power operation is maintained to minimize output deviations as well as providing full power load transients immediately after exiting a low power state. The user can program if one or two phases are enabled during PSI using the PSI_SET pin. If this pin is pulled low then 1 phase is enabled (always phase 1). If it is pulled high then two phases are enabled (phase 1 and phase 4 in a 6−phase or 5−phase system, phase 1 and phase 3 in a 4−phase system. Extreme care should be taken to ensure that OD1 is connected to all phases enabled during PSI. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |