4 / 16 page ![]() MODULE OVERVIEW ANALOG SECTION The analog (metering) interface described in this section is designed for measuring 230V/60A with precision better than Class 1. The most important external components for the SA9607 integrated circuit are the current sense resistors, the voltage sense resistors and the bias setting resistor. The resistors used in the metering section should be of the same type so temperature effects are minimized. Two current transformers are used to measure the current in the live and neutral phases. The output of the current transformer is terminated with a low impedance resistor. The voltage drop across the termination resistor is converted to a current that is fed to the differential current inputs of the SA9607. Current Input IIN1, IIP1, IIN2, IIP2 The termination resistor on the second current channel is adjustable by means of P2 to facilitate channel equalization calibration. The termination resistor is chosen so that a 10 trimpot in parallel will provide a sufficient channel range. The resistors R8, R9 and R10, R11 define the current level into the current sense inputs of the SA9607. The resistor values are selected for an input current of 16µA on the current inputs of the SA9607 at rated conditions. For a 60A meter at 2500:1 CT the resistor values are calculated as follows: R8=R9=(I / 16µA)xR /2 = 60A / 2500 / 16µA x 3.6 / 2 = 2.7k I Line current RSH = CT Termination resistor 2500 = CT ratio The two current channels are identical so R8 = R9 = R10 = R11. The voltage input of the SA9607 (IVP) is driven with a current of 14µA at nominal mains voltage. This voltage input saturates at approximately 17µA. At a nominal voltage current of 14µA allows for 20% overdriving. The mains voltage is divided with a voltage divider to 14V that is fed to the voltage input pins via a 1M resistor. The voltage divider is calculated for a voltage drop of 14V. Equations for the voltage divider in figure 4 are: RB=R1+R2+R3+R4 RB=R6||R5 W W W W Current Sensor Input Resistors Voltage Input Ivp Voltage Divider LSH L = sames PM9607AP R7 3.6R R8 2.7k R9 2.7k Live Line Neutral Line Live Load Neutral Load P1 10R CT2 Phase 2 CT1 Phase 1 R10 2.7k R11 2.7k R16 6.2R IIN1 GND GND DR-01576 IIP1 IIN2 IIP2 4/16 Figure 3: Current input configuration CT Termination Resistor The voltage drop across the CT termination resistor at rated current should be at least 20mV. The CTs have low phase shift and a ratio of 1:2500. The CT is terminated with a 3.6 resistor giving a voltage drop of 86.4mV across the termination resistor at rated conditions (Imax for the meter). W R1 120k R2 120k 120k R3 R4 10R/2W R5 24k R6 1M Live Neutral DR-01577 GND C4 1u/16V GND IVP TZ1 TZ GND Figure 4: Mains voltage divider http://www.sames.co.za |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |