| Electronic Components Datasheet Search |
|
PM9607AP Datasheet(PDF) 7 Page - Sames |
|
|
|||||||||||||||||||||||||||||
PM9607AP Datasheet(HTML) 7 Page - Sames |
|
7 / 16 page ![]() 7/16 sames PM9607AP Figure 7: Screen capture of the SA9607P setup program CALIBRATION AND SETUP Software is available to setup and calibrate the SA9607P device. Download the SA9607P1.zip file from the SAMES web site. From the following URL: The latest version of the evaluation software and source code is included in the zip file. The software was written with Borland C++ Ver 3 and should run on any PC with DOS operating system. The program was written as clear as possible so that it can easily be modified for specific needs. Start the program from the DOS prompt with: Use the cursor keys to move up and down between the parameters listed under the “SA9607P Meter Parameters” section. Press Enter on the parameter that needs to be changed. The options available will be displayed. Type in the correct option or value and press Enter again. The new setting will be displayed. A detailed description of the parameters listed on the screen are described in the SA9607P datasheet. The following is a description of the functionality of the SA9607P Meter Parameters, displayed on the PC’s screen, figure 7. http://www.sames.co.za/emsoft/9607-1.zip c:\>sa9607p 1 1000 NAVIGATING V and I LED Constant Counter Resol. Counter PW Channel1 Err / Channel2 Err nom ma x V and I make up the rated conditions of the module (SA9607P’s Kr parameter). V is the module’s rated voltage and I the module’s rated current. The PM9607AP module is designed for rated conditions of 230V/60A. The software defaults to V = 230V and I = 60A. LED Constant selects the module’s LED pulse rate (calibration LED), which is the SA9607P’s CLED parameter. The options available are 6400 p/kWh or 3200 p/kWh. Entering a ‘0’ will enable the 1252 pulses/second (at rated conditions) mode for fast calibration. Counter resolution sets the modules counter resolution (SA9607P’s CRES parameter). The options are 1,10 or 100p/kWh. Counter PW set up the mechanical counter’s pulse width (SA9607P’s CPW parameter). The available options are 71ms and 142 ms. The PM9607AP module uses an impulse counter with a pulse width of 71ms. The module may be calibrated by entering the percentage error in relation to a calibrated meter or Wh-Standard. The percentage error is calculated as follows: Error=(Energy from module – Real energy)/Real energy x 100 nom ma x ma x ma x nom nom http://www.sames.co.za |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |