Back Button AS8510 Datasheet HTML 19Page - ams AG AS8510 Datasheet HTML 20Page - ams AG AS8510 Datasheet HTML 21Page - ams AG AS8510 Datasheet HTML 22Page - ams AG AS8510 Datasheet HTML 23Page - ams AG AS8510 Datasheet HTML 24Page - ams AG AS8510 Datasheet HTML 25Page - ams AG AS8510 Datasheet HTML 26Page - ams AG AS8510 Datasheet HTML 27Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 46 page
background image
www.austriamicrosystems.com/AS8510
Revision 3.4
23 - 46
AS8510
Datasheet - Detailed Descr i p ti on
7.8.1 SPI Frame
A frame is formed by a first byte for command and address/configuration and a following bit stream that can be formed by an integer number of
bytes. Command is coded on the 1 first bit, while address is given on LSB 7 bits (see Table 30).
If the command is read or write, one or more bytes follow. When the micro-controller sends more bytes (keeping CS LOW and SCLK toggling),
the SPI interface increments the address of the previous data byte and writes/reads data to/from consecutive addresses.
7.8.2 Write Command
For write command, C0=0. After the command code C0 is transferred, the address of register to be written is provided from MSB to LSB.
Subsequently one or more data bytes can be transferred from MSB to LSB. For each data byte following the first one, used address is the
incremented value of the previously written address. Each bit of the frame has to be driven by the SPI master on the SPI clock transfer edge. The
SPI slave samples it on the next clock edge. These edges are determined by the level of SCLK as shown in Table 29. Figure 10 and Figure 11
are examples of write command without and with address self-increment.
Figure 10. Protocol for Serial Data Write with Length = 1
Table 30. Command Bits
Command Bits
Register Address or Transmission Configuration
C0
A6
A5
A4
A3
A2
A1
A0
Table 31. Command Bits
C0
Command
<A6:A0>
Description
0
WRITE
ADDRESS
Writes data byte on the given starting address.
1
READ
ADDRESS
Read data byte from the given starting address.
CS
SCLK
SDI
SDO
0
A6
A5
A4
A0
A1
A2
A3
D0
D1
D2
D3
D4
D5
D7
D6
Data D7 – D0 is moved
to Address A4..A0 here



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com