19 / 46 page ![]() CS5463 DS678F3 19 Output pin E3 is high when the line voltage is positive and pin E3 is low when the line voltage is negative. 5.5.5 PFMON Output Mode Setting bit E3MODE[1:0] = 1 (01b) in the Operational Mode Register outputs the state of the PFMON compar- ator on pin E3. Figure 8 illustrates the output format with PFMON on E3 When PFMON is greater then the threshold, pin E3 is high and when PFMON is less than the threshold pin E3 is low. 5.5.6 Design Example EXAMPLE #1: The maximum rated levels for a power line meter are 250 V rms and 20 A rms. The required number of puls- es-per-second on E1 is 100 pulses per second (100 Hz), when the levels on the power line are 220 V rms and 15 A rms. With a 10x gain on the voltage and current channel the maximum input signal is 250 mVP. (See Section 5.1 An- alog Inputs on page 16.) To prevent over-driving the channel inputs, the maximum rated rms input levels will register 0.6 in VRMS and IRMS by design. Therefore the voltage level at the channel inputs will be 150 mV rms when the maximum rated levels on the power lines are 250 V rms and 20 A rms. Solving for PulseRate using the transfer function: Therefore with PF = 1 and: the pulse rate is: and the PulseRateE Register is set to: with MCLK = 4.096 MHz and K = 1. 5.6 Sag and Fault Detect Feature Status bit VSAG and IFAULT in the Status Register, in- dicates a sag occurred in the power line voltage and current, respectively. For a sag condition to be identi- fied, the absolute value of the instantaneous voltage or current must be less than the sag level for more than half of the sag duration (see Figure 9). To activate voltage sag detection, a voltage sag level must be specified in the Voltage Sag Level Register (VSAGLevel), and a voltage sag duration must be spec- ified in the Voltage Sag Duration Register (VSAGDura- tion ). To activate current fault detection, a current sag level must be specified in the Current Fault Level Reg- ister (ISAGLevel), and a current sag duration must be specified in the Current Fault Duration Register (ISAG- Duration ). The voltage and current sag levels are speci- fied as the average of the absolute instantaneous voltage and current, respectively. Voltage and current sag duration is specified in terms of ADC cycles. 5.7 No Load Threshold The No Load Threshold register (LoadMin) is used to disable the active energy pulse output when the magni- tude of the PActive register is less than the value in the LoadMin register. 5.8 On-chip Temperature Sensor The on-chip temperature sensor is designed to assist in characterizing the measurement element over a desired temperature range. Once a temperature characteriza- tion is performed, the temperature sensor can then be utilized to assist in compensating for temperature drift. Temperature measurements are performed during con- tinuous conversions and stored in the Temperature Register . The Temperature Register (T) default is Cel- sius scale (°C). The Temperature Gain Register (Tgain) and Temperature Offset Register (Toff) are constant val- ues allowing for temperature scale conversions. E3 E2 E1 Above PFMON Threshold Below PFMON Threshold Figure 8. PFMON output to pin E3 PulseRate FREQ P VREFIN 2 VIN VGAIN IIN IGAIN PF --------------------------------------------------------------------------------------------- = VIN 220V 150mV 250V 132mV == IIN 15A 150mV 20A 112.5mV == PulseRate 100 2.5 2 0.132 10 0.1125 10 ----------------------------------------------------------------- 420.8754Hz == PulseRateE PulseRate MCLK K 2048 ---------------------------------------- 0.2104377 == Level Duration Figure 9. Sag and Fault Detect |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |