Electronic Components Datasheet Search
  English  ▼

X  

VSP01M02 Datasheet(PDF) 45 Page - Texas Instruments

Part # VSP01M02
Description  CCD Analog Front-End with Timing Generator and Vertical Driver for Digital Cameras
PDF  91 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

VSP01M02 Datasheet(HTML) 45 Page - Texas Instruments

Back Button VSP01M02 Datasheet HTML 41Page - Texas Instruments VSP01M02 Datasheet HTML 42Page - Texas Instruments VSP01M02 Datasheet HTML 43Page - Texas Instruments VSP01M02 Datasheet HTML 44Page - Texas Instruments VSP01M02 Datasheet HTML 45Page - Texas Instruments VSP01M02 Datasheet HTML 46Page - Texas Instruments VSP01M02 Datasheet HTML 47Page - Texas Instruments VSP01M02 Datasheet HTML 48Page - Texas Instruments VSP01M02 Datasheet HTML 49Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 45 / 91 page
background image
PowerOff
TGStandby
· PowerON
· SerialCodeInput
TGEnable
FrameNow
VA(n)
VD
TGDisable
FrameTRIG
VA(m)
TRIG
VD
VSP01M01
VSP01M02
www.ti.com .................................................................................................................................................................................................. SBES016 – MARCH 2009
Operated VA is updated to the Frame Now register by VD. Operated VA is updated to Frame TRIG by the TRIG
signal with a Load TRIG frame function. This updating process is shown in Table 38.
Table 38. Frame Mode Register
PARAMETER
REGISTER ADDRESS
DESCRIPTION
Set current frame number
Frame now
036h[2:0]
Default = 000b.
Set frame number when trigger input
Frame TRIG
036h[5:3]
Default = 000b.
Figure 39 shows the TG mode transition.
Figure 39. TG Mode Transition
Figure 40 shows the CCD timing composition example, which consists of frames for several operation modes.
Each frame counts the line count. VD (master/slave) or TRIG (external trigger) signal the reset line counter and
change during the next frame.
Table 39. TRIG Frame Function Register Setting(1)(2)
PARAMETER
REGISTER ADDRESS
VALUE
VD frame
022h[0]
1 = Enabled
TRIG frame INCR
021h[2]
1 = Enabled
TRIG counter RST
021h[3]
1 = Enabled
Static frame number
036h[2:0]
—
TRIG frame number
036h[5:3]
7
(1)
If the TRIG function is not used, TRIG Frame INCR and TRIG Counter RST should be disabled. Refer to the TRIG Function Section of
this document
(2)
Refer to the Configuration Register section for details.
Copyright © 2009, Texas Instruments Incorporated
Submit Documentation Feedback
45
Product Folder Link(s): VSP01M01 VSP01M02



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com