| Electronic Components Datasheet Search |
|
MJD243 Datasheet(PDF) 2 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
MJD243 Datasheet(HTML) 2 Page - Motorola, Inc |
|
2 / 6 page ![]() MJD243 2 Motorola Bipolar Power Transistor Device Data ELECTRICAL CHARACTERISTICS (TC = 25_C unless otherwise noted) Characteristic Symbol Min Max Unit OFF CHARACTERISTICS Collector–Emitter Sustaining Voltage (1) (IC = 10 mAdc, IB = 0) VCEO(sus) 100 — Vdc Collector Cutoff Current (VCB = 100 Vdc, IE = 0) Collector Cutoff Current (VCB = 100 Vdc, IE = 0, TJ = 125_C) ICBO — — 100 100 nAdc µAdc Emitter Cutoff Current (VBE = 7 Vdc, IC = 0) IEBO — 100 nAdc DC Current Gain (1) (IC = 200 mAdc, VCE = 1 Vdc) DC Current Gain (1) (IC = 1 Adc, VCE = 1 Vdc) hFE 40 15 180 — — Collector–Emitter Saturation Voltage (1) (IC = 500 mAdc, IB = 50 mAdc) (IC = 1 Adc, IB = 100 mAdc) VCE(sat) — — 0.3 0.6 Vdc Base–Emitter Saturation Voltage (1) (IC = 2 Adc, IB = 200 mAdc) VBE(sat) — 1.8 Vdc Base–Emitter On Voltage (1) (IC = 500 mAdc, VCE = 1 Vdc) VBE(on) — 1.5 Vdc DYNAMIC CHARACTERISTICS Current–Gain — Bandwidth Product (2) (IC = 100 mAdc, VCE = 10 Vdc, ftest = 10 MHz) fT 40 — MHz Output Capacitance (VCB = 10 Vdc, IE = 0, f = 0.1 MHz) Cob — 50 pF (1) Pulse Test: Pulse Width = 300 µs, Duty Cycle [ 2%. (2) fT = hFE• ftest. Figure 2. Active Region Maximum Safe Operating Area 10 VCE, COLLECTOR–EMITTER VOLTAGE (VOLTS) 0.01 100 2 5 0.1 BONDING WIRE LIMITED THERMALLY LIMITED @ TC = 25°C (SINGLE PULSE) SECOND BREAKDOWN LIMITED CURVES APPLY BELOW RATED VCEO 500 µs dc 1 1 ms 50 20 10 5 2 1 100 µs 0.02 0.05 0.2 0.5 5 ms There are two limitations on the power handling ability of a transistor: average junction temperature and second break- down. Safe operating area curves indicate IC – VCE limits of the transistor that must be observed for reliable operation; i.e., the transistor must not be subjected to greater dissipa- tion than the curves indicate. The data of Figure 2 is based on TJ(pk) = 150_C; TC is variable depending on conditions. Second breakdown pulse limits are valid for duty cycles to 10% provided TJ(pk) v 150_C. TJ(pk) may be calculated from the data in Fig- ure 3. At high case temperatures, thermal limitations will re- duce the power that can be handled to values less than the limitations imposed by second breakdown. t, TIME (ms) 0.01 0.02 0.05 1 2 5 10 20 50 100 200 0.1 0.5 0.2 1 0.2 0.1 0.05 R θJC(t) = r(t) θJC R θJC = 10°C/W MAX D CURVES APPLY FOR POWER PULSE TRAIN SHOWN READ TIME AT t1 TJ(pk) – TC = P(pk) θJC(t) P(pk) t1 t2 DUTY CYCLE, D = t1/t2 0.2 0.5 D = 0.5 0.05 0.3 0.7 0.07 0.03 0.02 0 (SINGLE PULSE) Figure 3. Thermal Response 0.1 0.02 0.01 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |