| Electronic Components Datasheet Search |
|
AD8400 Datasheet(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD8400 Datasheet(HTML) 12 Page - Analog Devices |
|
12 / 20 page ![]() AD8400/AD8402/AD8403 –12– REV. B PROGRAMMING THE VARIABLE RESISTOR Rheostat Operation The nominal resistance of the VR (RDAC) between terminals A and B are available with values of 1 k Ω, 10 kΩ, 50 kΩ and 100 kΩ. The final digits of the part number determine the nominal resis- tance value, e.g., 10 k Ω = 10; 100 kΩ = 100. The nominal resis- tance (RAB) of the VR has 256 contact points accessed by the wiper terminal, plus the B terminal contact. The 8-bit data word in the RDAC latch is decoded to select one of the 256 possible settings. The wiper’s first connection starts at the B terminal for data 00H. This B terminal connection has a wiper contact resis- tance of 50 Ω. The second connection (10 kΩ part) is the first tap point located at 89 Ω [= R BA (nominal resistance)/256 + RW = 39 Ω + 50 Ω] for data 01 H. The third connection is the next tap point representing 78 + 50 = 128 Ω for data 02 H. Each LSB data value increase moves the wiper up the resistor ladder until the last tap point is reached at 10011 Ω. The wiper does not di- rectly connect to the B terminal. See Figure 37 for a simplified diagram of the equivalent RDAC circuit. The AD8400 contains one RDAC, the AD8402 contains two independent RDACs and the AD8403 contains four independent RDACs. The general transfer equation that determines the digi- tally programmed output resistance between Wx and Bx is: RWB (Dx) = (Dx)/256 × RBA + RW Equation 2 where Dx is the data contained in the 8-bit RDAC# latch, and RBA is the nominal end-to-end resistance. For example, when VB = 0 V and A terminal is open circuit, the following output resistance values will be set for the following RDAC latch codes (applies to 10 k Ω potentiometers): DRWB (Dec) ( Ω) Output State 255 10011 Full Scale 128 5050 Midscale (RS = 0 Condition) 1 89 1 LSB 0 50 Zero-Scale (Wiper Contact Resistance) Note in the zero-scale condition a finite wiper resistance of 50 Ω is present. Care should be taken to limit the current flow be- tween W and B in this state to a maximum value of 5 mA to avoid degradation or possible destruction of the internal switch contact. Like the mechanical potentiometer the RDAC replaces, it is to- tally symmetrical. The resistance between the wiper W and ter- minal A also produces a digitally controlled resistance RWA. When these terminals are used the B terminal should be tied to the wiper. Setting the resistance value for RWA starts at a maxi- mum value of resistance and decreases as the data loaded in the RDAC latch is increased in value. The general transfer equation for this operation is: RWA (Dx) = (256–Dx)/256 × R BA + RW Equation 3 OPERATION The AD8400/AD8402/AD8403 provide a single, dual and quad channel, 256 position digitally controlled variable resistor (VR) device. Changing the programmed VR settings is accomplished by clocking in a 10-bit serial data word into the SDI (Serial Data Input) pin. The format of this data word is two address bits, MSB first, followed by eight data bits, MSB first. Table I provides the serial register data word format. The AD8400/ AD8402/AD8403 has the following address assignments for the ADDR decode, which determines the location of VR latch re- ceiving the serial register data in Bits B7 through B0: VR# = A1 × 2 + A0 + 1 Equation 1 The single-channel AD8400 requires A1 = A0 = 0. The dual- channel AD8402 requires A1 = 0. VR settings can be changed one at a time in random sequence. The serial clock running at 10 MHz makes it possible to load all 4 VRs in under 4 µs (10 × 4 × 100 ns) for the AD8403. The exact timing requirements are shown in Figures 1a, 1b and 1c. The AD8402/AD8403 resets to midscale by asserting the RS pin, simplifying initial conditions at power up. Both parts have a power shutdown SHDN pin that places the VR in a zero power consumption state where terminals Ax are open circuited and the wiper Wx is connected to Bx resulting in only leakage cur- rents being consumed in the VR structure. In shutdown mode the VR latch settings are maintained so that returning to opera- tional mode from power shutdown, the VR settings return to their previous resistance values. The digital interface is still ac- tive in shutdown, except that SDO is deactivated. Code changes in the registers can be made that will produce new wiper posi- tions when the device is taken out of shutdown. D7 D6 D5 D4 D3 D2 D1 D0 RDAC LATCH & DECODER Ax Wx Bx RS = RNOMINAL/256 RS RS RS RS SHDN Figure 37. AD8402/AD8403 Equivalent VR (RDAC) Circuit |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |