  ADG802 Datasheet HTML 1Page - Analog Devices ADG802 Datasheet HTML 2Page - Analog Devices ADG802 Datasheet HTML 3Page - Analog Devices ADG802 Datasheet HTML 4Page - Analog Devices ADG802 Datasheet HTML 5Page - Analog Devices ADG802 Datasheet HTML 6Page - Analog Devices ADG802 Datasheet HTML 7Page - Analog Devices ADG802 Datasheet HTML 8Page - Analog Devices ADG802 Datasheet HTML 9Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 5 / 9 page
background image
ADG801/ADG802
–5–
REV. PrE
PRELIMINARY TECHNICAL DATA
TERMINOLOGY
VDD
Most positive power supply potential.
IDD
Positive supply current.
GND
Ground (0 V) reference.
S
Source terminal. May be an input or output.
D
Drain terminal. May be an input or output.
IN
Logic control input.
VD (VS)
Analog voltage on terminals D, S
RON
Ohmic resistance between D and S.
RFLAT(ON)
Flatness is defined as the difference between the maximum and minimum value of on-resistance as measured
over the specified analog signal range.
IS (OFF)
Source leakage current with the switch “OFF.”
ID (OFF)
Drain leakage current with the switch “OFF.”
ID, IS (ON)
Channel leakage current with the switch “ON.”
VINL
Maximum input voltage for logic “0”.
VINH
Minimum input voltage for logic “1”.
IINL(IINH)
Input current of the digital input.
CS (OFF)
“OFF” switch source capacitance. Measured with reference to ground.
CD (OFF)
“OFF” switch drain capacitance. Measured with reference to ground.
CD,CS(ON)
“ON” switch capacitance. Measured with reference to ground.
CIN
Digital input capacitance.
tON
Delay between applying the digital control input and the output switching on. See Test Circuit 4.
tOFF
Delay between applying the digital control input and the output switching off.
Charge
A measure of the glitch impulse transferred from the digital input to the analog output during switching.
Injection
Off Isolation
A measure of unwanted signal coupling through an “OFF” switch.
Crosstalk
A measure of unwanted signal which is coupled through from one channel to another as a result of parasitic
capacitance.
Bandwidth
The frequency at which the output is attenuated by 3dBs.
On Response The Frequency response of the “ON” switch.
Insertion
The loss due to the ON resistance of the switch.
Loss



Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com