12 / 24 page ![]() LM48100Q SNAS470D – OCTOBER 2008 – REVISED MARCH 2013 www.ti.com In continuous diagnostic mode, the test sequence is repeated until either a fault condition occurs, DG_RESET is cycled, or the device is taken out of continuous diagnostic mode. Set DG_CONT = 1 before setting DG_EN = 1 to initiate a continuous diagnostic. Set DG-CONT = 0 to disable continuous diagnostic mode. When the device is active and DG_EN = 0, the LM48100Q does not perform the output short, or no load diagnostics, however, the thermal overload and output over current protection circuitry remains active, and disables the device should a thermal or over-current fault occur. The initial diagnostic operation when power is applied to the device occurs regardless of the state of DG_EN. The LM48100Q output fault detection can be set to either continuous mode where the output diagnostic occurs every 60ms, or a one-shot mode. Set bit B3 (DG_CONT) to 1 for continuous mode, set B3 = 0 for one-shot mode. Bit B2, DG_RESET, restores the LM48100Q to normal operation after an output fault is detected. Toggle DG_RESET to re-enable the device outputs and set FAULT high. Table 4. Diagnostic Control Register BIT NAME VALUE DESCRIPTION B0 RESERVED 0 Unused 0 Fixed output current limit B1 ILIMIT 1 Supply dependent output current limit Normal operation. FAULT remains low and device is disabled 0 DG once a fault occurs. B2 _RESET 1 Reset FAULT output. Device returns to pre-fault operation. 0 One shot diagnostic DG B3 _CONT 1 Continuous diagnostic 0 Disable diagnostic B4 DG_EN 1 Enable diagnostic FAULT DETECTION CONTROL REGISTER The LM48100Q output fault tests are individually controlled through the Fault Detection Control register, register 2. Setting any of the bits in the Fault Detection Control register to 1 causes the FAULT circuitry to ignore the associated test. For example, if B2 (RAIL_SHT) = 1 and the output is shorted to VDD, the FAULT output remains high. Although the FAULT circuitry ignores the selected test, the LM48100Q protection circuitry remains active, and disables the device. This feature is useful for diagnosing which fault caused a FAULTcondition. If DG_EN = 1, and a diagnostic sequence is initiated, all the tests are performed regardless of their state in the Fault Detection Control register. If DG_EN = 0, the RAIL_SHT, OUTPUT_OPEN and OUTPUT_SHT tests are not performed, however, the thermal overload and output over-current detection circuitry remains active. Table 5. Fault Detection Control Register BIT NAME VALUE DESCRIPTION 0 Normal operation B0 OUTPUT_SHT 1 Ignore output short circuit fault (outputs shorted together) 0 Normal operation B1 OUTPUT_OPEN 1 Ignore output short circuit fault 0 Normal operation RAIL B2 _SHT 1 Ignore output short to VDD or GND fault 0 Normal operation B3 OVF 1 Ignore output over-current fault 0 Normal operation B4 TSD 1 Ignore thermal overload fault 12 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated Product Folder Links: LM48100Q |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |