23 / 36 page ![]() –23– REV. B AD7851 System Gain and Offset Interaction The inherent architecture of the AD7851 leads to an interaction between the system offset and gain errors when a system calibra- tion is performed. Therefore, it is recommended to perform the cycle of a system offset calibration followed by a system gain cali- bration twice. Separate system offset and system gain calibrations reduce the offset and gain errors to at least the 14-bit level. By performing a system offset calibration first and a system gain calibration second, priority is given to reducing the gain error to zero before reducing the offset error to zero. If the system errors are small, a system offset calibration would be performed, fol- lowed by a system gain calibration. If the systems errors are large (close to the specified limits of the calibration range), this cycle would be repeated twice to ensure that the offset and gain errors were reduced to at least the 14-bit level. The advantage of doing separate system offset and system gain calibrations is that the user has more control over when the analog inputs need to be at the required levels, and the CONVST signal does not have to be used. Alternatively, a system (gain + offset) calibration can be per- formed. It is recommended to perform three system (gain + offset) calibrations to reduce the offset and gain errors to the 14-bit level. For the system (gain + offset) calibration priority is given to reducing the offset error to 0 before reducing the gain error to 0. Thus, if the system errors are small then two system (gain + offset) calibrations will be sufficient. If the system errors are large (close to the specified limits of the calibration range), three system (gain + offset) calibrations may be required to reduce the offset and gain errors to at least the 14-bit level. There will never be any need to perform more than three system (offset + gain) calibrations. In bipolar mode, the midscale error is adjusted for an offset cali- bration and the positive full-scale error is adjusted for the gain calibration; in unipolar mode, the zero-scale error is adjusted for an offset calibration and the positive full-scale error is adjusted for a gain calibration. System Calibration Timing The calibration timing diagram in Figure 31 is for a full system calibration where the falling edge of CAL initiates an internal reset before starting a calibration (note that if the part is in power- down mode the CAL pulse width must take account of the power-up time). If a full system calibration is performed in the software, it is easier to perform separate gain and offset calibrations so that the CONVST bit in the control register does not have to be programmed in the middle of the system calibration sequence. The rising edge of CAL starts calibration of the internal DAC and causes the BUSY line to go high. If the control register is set for a full system calibration, the CONVST must be used also. The full-scale system voltage should be applied to the ana- log input pins from the start of calibration. The BUSY line will go low once the DAC and system gain calibration are complete. Next, the system offset voltage is applied to the AIN pin for a minimum setup time (tSETUP) of 100 ns before the rising edge of the CONVST and remains until the BUSY signal goes low. The rising edge of the CONVST starts the system offset calibration section of the full system calibration and also causes the BUSY signal to go high. The BUSY signal will go low after a time tCAL2 when the calibration sequence is complete. The timing for a system (gain + offset) calibration is very similar to that of Figure 31, the only difference being that the time tCAL1 will be replaced by a shorter time of the order of tCAL2 as the internal DAC will not be calibrated. The BUSY signal will signify when the gain calibration is finished and when the part is ready for the offset calibration. CONVST (I/P) AIN (I/P) t16 tSETUP CAL (I/P) BUSY (O/P) t1 t15 tCAL1 tCAL2 VSYSTEM FULL SCALE VOFFSET t1 = 100ns MIN, t14 = 50 MAX, t15 = 4 tCLKIN MAX, tCAL1 = 222228 tCLKIN MAX, tCAL2 = 27798 tCLKIN Figure 31. Timing Diagram for Full System Calibration The timing diagram for a system offset or system gain calibration is shown in Figure 32. Here again the CAL is pulsed and the rising edge of the CAL initiates the calibration sequence (or the calibra- tion can be initiated in software by writing to the control register). The rising edge of the CAL causes the BUSY line to go high and it will stay high until the calibration sequence is finished. The analog input should be set at the correct level for a minimum setup time (tSETUP) of 100 ns before the rising edge of CAL and stay at the correct level until the BUSY signal goes low. AIN (I/P) t SETUP CAL (I/P) BUSY (O/P) t15 tCAL2 t1 VSYSTEM FULL SCALE OR VSYSTEM OFFSET Figure 32. Timing Diagram for System Gain or System Offset Calibration |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |