3055 Datasheet(PDF) 4 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
3055 Datasheet(HTML) 4 Page - Allegro MicroSystems |
|
4 / 8 page ![]() 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 3055 MULTIPLEXED TWO-WIRE HALL EFFECT SENSOR IC ADDRESSING PROTOCOL The device may be addressed by modulating the supply voltage as shown in Figure 1. A preferred addressing protocol is as follows: the bus supply voltage is brought down to 0V so that all devices on the bus may be reset. The voltage is then raised to the address LOW voltage (V L) and the bus quiescent current is measured. The bus is then toggled between V L and VH (address HIGH voltage), with each positive transition representing an increment in the bus address. After each voltage transition, the bus current is moni- tored to check for diagnostic and signal responses from sensor ICs. Sensor Addressing When a sensor detects a bus address equal to its factory programmed address, it re- sponds with an increase in its supply current drain (called I S during the HIGH portion of the address cycle). This response may be used as an indication that the sensor is alive and well on the bus and is also called the diagnostic response. If the sensor detects an ambient magnetic field, it also responds with I S during the low portion of the address cycle. This response from the sensor is called the signal response. When the next positive transition is detected, the sensor becomes disabled, and its contribution to the bus signal current returns to I Q. Bus Current Figure 1 displays the above described addressing protocol. The top trace represents the bus voltage transitions as controlled by the bus driver (see applications note for an optimal bus driver schematic). The second trace represents the bus current contribution of sensor (ad- dress 02). The diagnostic response from the sensor indicates that it detected its address on the bus; however, no signal response current is returned, which indicates that sufficient magnetic field is not de- tected at the chip surface. The third trace represents the current drain of sensor 03 when a magnetic field is detected. Note both the diag- nostic and signal response from the sensor. The last trace represents FIGURE 1 BUS TIMING D1 SENSOR 03 — DIAGNOSTIC AND SIGNAL CURRENTS DIAGNOSTIC ADDRESS 01 DIAGNOSTIC ADDRESS 02 DIAGNOSTIC ADDRESS 04 DIAGNOSTIC ADDRESS n RESET DIAGNOSTIC ADDRESS 01 SENSOR 02 — DIAGNOSTIC CURRENT DIAGNOSTIC ADDRESS 03 SENSOR 01 NOT PRESENT V H V L V RST 0 IS I QL I QH 0 I S 0 I S n • I QL n • IQH 0 t phl t plh V CLH V CHL Dwg. WH-005 BUS VOLTAGE SENSOR 02 CURRENT WITH NO MAGNETIC FIELD SENSOR 03 CURRENT WITH MAGNETIC FIELD TOTAL BUS CURRENT WITH MAGNETIC FIELD AT SENSOR 03 RESET I QL I QH SENSOR 01 NOT PRESENT |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |