| Electronic Components Datasheet Search |
|
3961 Datasheet(PDF) 5 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
3961 Datasheet(HTML) 5 Page - Allegro MicroSystems |
|
5 / 10 page ![]() 3961 DUAL FULL-BRIDGE PWM MOTOR DRIVER internal current-control circuitry (or by the PHASE or ENABLE inputs). The comparator output is blanked to prevent false over-current detections due to reverse- recovery currents of the clamp diodes, and/or switching transients related to distributed capacitance in the load. During internal PWM operation, at the end of the tOFF time, the comparator’s output is blanked and CT begins to be charged from approximately 1.1 volts by an internal current source of approximately 1 mA. The comparator output remains blanked until the voltage on CT reaches approximately 3.0 volts. When a transition of the PHASE input occurs, CT is discharged to near ground during the crossover delay time (The crossover delay time is present to prevent simultaneous conduction of the source and sink drivers). After the crossover delay, CT is charged by an internal cur- rent source of approximately 1 mA. The comparator out- put remains blanked until the voltage on CT reaches approximately 3.0 volts. When the device is disabled, via the ENABLE input, CT is discharged to near ground. When the device is re-enabled, CT is charged by an internal current source of approximately 1 mA. The comparator output remains blanked until the voltage on CT reaches approximately 3.0 volts. The minimum recommended value for CT is 1000 pF. This value ensures that the blanking time is suffi- cient to avoid false trips of the comparator under normal operating conditions. For optimal regulation of the load current, the above value for CT is recommended and the value of RT can be sized to determine tOFF. For more infor- mation regarding load current regulation, see below. Load Current Regulation. Because the device operates in a slow decay mode (2-quadrant PWM mode), there is a limit to the lowest level that the PWM current control cir- cuitry can regulate load current. The limitation is due to the minimum PWM duty cycle, which is a function of the user- selected value of tOFF and the minimum on-time pulse tON(min)max that occurs each time the PWM latch is reset. If the motor is not rotating, as in the case of a stepper mo- tor in hold/detent mode, a brush dc motor when stalled or at startup, the worst case value of current regulation can be approximated by: FUNCTIONAL DESCRIPTION Internal PWM Current Control. The A3961S— contains a fixed off-time pulse-width modulated (PWM) current- control circuit that can be used to limit the load current to a desired value. The peak value of the current limiting (ITRIP) is set by the selection of an external current-sensing resistor (RS) and reference input voltage (VREF IN). The internal circuitry compares the voltage across the external sense resistor to the voltage on the reference input terminal (VREF IN), resulting in a transconductance function approximated by: The reference input voltage is typically set with a resistor divider from VREF OUT. The value of VREF OUT can be switched from a nominal value of 2.5 V to 1.67 V by applying a low or high logic signal respectively to the I FULL/PD terminal. To ensure proper operation of the voltage reference, the resistor divider (RD = R1+R2) should have an impedance of 3 k Ω to 15 kΩ. Within this range, a low impedance will minimize the effect of the REF IN input offset current. The current-control circuitry limits the load current as follows: when the load current reaches ITRIP, the compara- tor resets a latch that turns off the selected source driver. The load inductance causes the current to recirculate through the sink driver and flyback diode. For each bridge, the user selects an external resistor (RT) and capacitor (CT) to determine the time period (tOFF = RTCT) during which the source driver remains dis- abled (see “RC Fixed Off-time” below). The range of rec- ommended values for CT and RT are 1000 pF to 1500 pF and 15 k Ω to 100 kΩ respectively. For optimal load current regulation, CT is normally set to 1000 pF (see “Load Current Regulation” below). At the end of the RC in- terval, the source driver is enabled allowing the load cur- rent to increase again. The PWM cycle repeats, maintain- ing the peak load current at the desired value. RC BLANKING. In addition to determining the fixed off- time of the PWM control circuit, the CT component sets the comparator blanking time. This function blanks the output of the comparator when the outputs are switched by the ITRIP ≈ VREF IN RS [(VBB - VSAT(SOURCE+SINK)) tON(min)max] – (1.05 (VSAT(SINK) + VF) tOFF) 1.05 (tON(min)max + tOFF) RLOAD I AVG ≈ |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |