| Electronic Components Datasheet Search |
|
HF81GS Datasheet(PDF) 6 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
HF81GS Datasheet(HTML) 6 Page - Monolithic Power Systems |
|
6 / 10 page ![]() HF81 – X CAPACITOR BLEEDER HF81 Rev. 1.12 www.MonolithicPower.com 6 11/15/2012 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2012 MPS. All Rights Reserved. OPERATION A smart bleeder normally works as an off device: It consumes very little current, it always monitors the AC line for zero crossings; whenever it detects a zero crossing it dischargers the timer capacitor and resets the latch circuit. Whenever a prolonged period occurs without a zero crossing (meaning the power supply unit [PSU] was unplugged from the utility line), the timer block times out and triggers the latch circuit. The latch circuit turns on the discharging transistors, as shown by the timing diagram in Figure 1. The internal transistor enables the bleed resistors, and stops when either the voltage across the HF81 drops below 10V or the PSU is plugged back into the utility line. This operation allows for more X capacitor choices and reduces the inductor cost. Figure 1: Zero-Crossing Detection Timing COMPONENT SELECTION According to international safety requirements, the X capacitor voltage must drop to 37% within 1s. Based on a 5% tolerance for the discharge resistor and a 20% tolerance for the X capacitor, select an RC time constant of 0.75s. Table 1 provides sample values for the X capacitor and the discharge resistance. Carefully select a metal oxide varistor (MOV) and fuse to meet safety requirements: The MOV suppresses voltage transients. During normal operation, a MOV with high impedance permits only a small current. When a voltage surge occurs, the MOV resistance reduces to a few Ωs, which allows the large surge current to flow through while protecting other devices in parallel to it. There are several parameters for selecting a MOV, including maximum-allowable voltage, maximum clamping voltage, and the MOV max endured energy. The maximum-allowable voltage must exceed the maximum working voltage by 10%, 20% or the circuit needs an even higher derating, which is determined by the power source stability. After selecting a MOV, verify it using V1mA, which is the voltage across the MOV the current is 1mA. Simplified, this is: 1mA peak AC V 1.5V 2.2V (1) Where Vpeak is the peak working voltage and VAC is the rms working voltage. Also, please make sure the breakdown voltage of other components on the AC side fall below the maximum allowable voltage. Base MOV size selection on MOV withstanding transient energy. Calculate the energy using formula 2. Clamp Peak WK V I t ( 2) Where K is a constant 1.0 for rectangular waveform and 1.4 for 8/20µs and 10/1000µs waveform, VClamp is the maximum clamping voltage, and IPeak is the peak applied current. Make sure that the calculated energy is lower than the rated energy on the MOV datasheet. Select the fuse based on MOV specification. Generally, select the fuse based on MOV diameter as per Table 2. Zero Crossing Detection Timing VXCap 100V/div 22ms |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |