Electronic Components Datasheet Search
  English  ▼

X  

MP6219DN Datasheet(PDF) 9 Page - Monolithic Power Systems

Part # MP6219DN
Description  5V, 1A ??2A Programmable Current Limit Power Distribution Switch
PDF  11 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

MP6219DN Datasheet(HTML) 9 Page - Monolithic Power Systems

Back Button MP6219DN Datasheet HTML 3Page - Monolithic Power Systems MP6219DN Datasheet HTML 4Page - Monolithic Power Systems MP6219DN Datasheet HTML 5Page - Monolithic Power Systems MP6219DN Datasheet HTML 6Page - Monolithic Power Systems MP6219DN Datasheet HTML 7Page - Monolithic Power Systems MP6219DN Datasheet HTML 8Page - Monolithic Power Systems MP6219DN Datasheet HTML 9Page - Monolithic Power Systems MP6219DN Datasheet HTML 10Page - Monolithic Power Systems MP6219DN Datasheet HTML 11Page - Monolithic Power Systems  
Zoom Inzoom in Zoom Outzoom out
 9 / 11 page
background image
MP6219 – PROGRAMMABLE CURRENT LIMIT (2A) POWER DISTRIBUTION SWITCH
MP6219 Rev.0.93
www.MonolithicPower.com
9
10/20/2010
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.
© 2010 MPS. All Rights Reserved.
CURRENT LIMIT
The desired current limit is a function of the
external current limit resistor.
Table1-Current Limit vs. Current Limit Resistor
(VIN=5V)
Current Limit Resistor
24Ω
50Ω
100Ω
Trip Current
3.0A
2.25A
2.0A
Hold Current
2.0A
1.1A
0.6A
When the part is active, if load reaches trip
current (minimum threshold current triggering
overcurrent protection) or a short is present, the
part switches into to a constant-current (hold
current) mode. Part will be shutdown only if the
overcurrent condition stays long enough to
trigger thermal protection.
However, when the part is powered up by VCC or
EN, the load current should be smaller than hold
current. Otherwise, the part can’t be fully turned
on.
In a typical application using a current limit
resistor of 24Ω, the trip current will be 3A and the
hold current will be 2A. If the device is in its
normal operating state and passing 2A it will
need to dissipate only 176mW with the very low
on resistance of 44mΩ. For the package
dissipation of 50°C/Watt, the temperature rise will
only be + 8.8°C. Combined with a 25°C ambient,
this is only 33.8°C total package temperature.
During a short circuit condition, the device now
has 5V across it and the hold current clamps at
2A and therefore must dissipate 10W. At
50°C/watt, if uncontrolled, the temperature would
rise above the thermal protection threshold
(+175°C) and the device will shutdown to cause
the temperature to drop.
Proper heat sink must be used if the device is
intended to supply the hold current and not
shutdown. Without a heat sink, hold current
should be maintained below 600mA at + 25°C
and below 360mA at +85°C to prevent the device
from activating the thermal shutdown feature.
EN/FAULT PIN
The EN/Fault Pin is a Bi-Directional three level
I/O with a weak pull up current (28uA typical).
The three levels are low, mid and high. It
functions to enable/disable the part and to relay
Fault information.
EN/Fault pin as an input:
1. Low and mid disable the part.
2. Low, in addition to disabling the part,
clears the fault flag.
3. High enables the part (if the fault flag is
clear).
EN/Fault pin as an output:
1. The pull up current may (if not over
ridden) allow a “wired nor” pull up to
enable the part.
2. An under voltage will cause a low on the
EN/Fault pin, and will clear the fault flag.
3. A thermal fault will cause a mid level on
the EN/Fault pin, and will set the fault
flag.
The EN/Fault line must be above the mid level for
the output to be turned on.
The fault flag is a internal flip-flop that can be set
or reset under various conditions:
1. Thermal Shutdown: set fault flag
2. Under Voltage: reset fault flag
3. Low voltage on EN/Fault pin: reset fault
flag
4. Mid voltage on EN/Fault pin: no effect
Under a fault, the EN/Fault pin is driven to the
mid level.
There are 4 types of faults, and each fault has a
direct and indirect effect on the EN/Fault pin and
the internal fault flag.
In a typical application where there are multiple
MP6219 chips in a system, the EN/Fault lines are
typically connected together.



Html Pages

1 2 3 4 5 6 7 8 9 10 11


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com