Back Button RX62T Datasheet HTML 15Page - Renesas Technology Corp RX62T Datasheet HTML 16Page - Renesas Technology Corp RX62T Datasheet HTML 17Page - Renesas Technology Corp RX62T Datasheet HTML 18Page - Renesas Technology Corp RX62T Datasheet HTML 19Page - Renesas Technology Corp RX62T Datasheet HTML 20Page - Renesas Technology Corp RX62T Datasheet HTML 21Page - Renesas Technology Corp RX62T Datasheet HTML 22Page - Renesas Technology Corp RX62T Datasheet HTML 23Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 25 page
background image
RX62T
Position Control of PMSM with Encoder
R01AN0899EU0200 Rev. 2.00
Page 19 of 22
Jan. 31, 2014
8.
Motor and Position Control Parameters
8.1 Tuning through header file
According to the motor data sheet and position control requirements, motor and control parameters, and motion profile
should be properly tuned.
Motor and control parameters required in the code of “customize.h” include:
 #define ENC_EDGES_CUSTOM
4000
// total encoder Edges/Revolution
 #define PWM_FREQ_CUSTOM
16000
// PWM Frequency in Hz
 #define SAM_FREQ_CUSTOM
16000
// Sample Frequency in Hz
 #define C_POLI_CUSTOM
4
// polar couples number
 #define R_STA_CUSTOM
8
// stator phase resistance in Ohm/OHM_DIV
 #define L_SYN_CUSTOM
10
// synchronous inductance in Henry/HEN_DIV
 #define POS_MIN_CUSTOM
0
// minimum position in counts
 #define POS_MAX_CUSTOM
40000
// maximum position in counts
 #define KP_CUR_CUSTOM
60
// K prop. current control
 #define KI_CUR_CUSTOM
80
// K integ. current control
 #define K_P_POSITION
10
// K prop. position control
 #define K_I_POSITION
12
// K integ. position control
 #define K_D_POSITION
150
// K derivative psotion control
8.2 Operation through GUI
The motor and control parameters can be tuned through Renesas friendly graphic user interface as shown in Figure 18.
Without modifying the code, the parameters can be set for the different motors and applications. There is a parameter
window to set up 20 parameters. Scrolling up and down through these parameters, the user can make changes to the
settings, and “Write” to EEPROM, but this doesn’t change the “customize.h” file. The original values will be restored
upon RESET. From Figure 19, it can be seen that these parameters mirror the #defines in the “customize.h” file. The
motor and control parameters can be easily changed by the GUI.
In the meantime, the GUI has position control window to set the commanded position, and display the motor actual
operation status.
Figure 18 GUI interface of evaluation kit



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com