| Electronic Components Datasheet Search |
|
LTC1325CSW Datasheet(PDF) 11 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC1325CSW Datasheet(HTML) 11 Page - Linear Technology |
|
11 / 24 page ![]() 11 LTC1325 FUNCTIONAL DESCRIPTIO Bits 21 and 22: Charging Loop Reference Voltage Select (VR0 and VR1) VR1 and VR0 select the desired reference voltage VCHRG for the charging loop. The charging loop will force the average voltage at the Sense pin to be equal to VDAC. The average charging current is VDAC/RSENSE (see Figure 4). VR1 VR0 VDAC (mV) 00 18 01 34 10 55 1 1 160 STATUS WORD The status word is 8 bits long and contains the status of the internal fail-safe circuits. Bit 1: Battery Present (BATP) The BATP bit = 1 indicates the presence of the battery. The bit is set to 1 when the voltage at the VBAT pin falls below (VDD – 1.8V). BATP = 0 when the battery is removed and VBAT is pulled high by RTRK (see Figure 3). BATP CONDITIONS 0(VDD – 1.8) < VBAT < VDD 1VBAT < (VDD – 1.8) Bit 2: Battery Reversed (BATR) or Shorted The BATR bit indicates when the battery is connected backwards or shorted. The bit is set when the battery cell voltage at the output of the battery divider VCELL is below 100mV. BATR CONDITIONS 0VCELL > 100mV 1VCELL < 100mV BATP 1 BATR 2 FMCV 3 FEDV 4 FHTF 5 FLTF 6 tOUT 7 FS 8 LTC1325 • F02 Figure 2. Status Word Bit 13: Power Shutdown (PS) PS selects between the normal operating mode, or the shutdown mode. PS DESCRIPTION 0 Normal Operation 1 Shutdown All Circuits Except Digital Inputs Bits 14 to 16: Duty Ratio Select (DR0 to DR2) DR2, DR1 and DR0 select the duty cycle of the charging loop operation (not 111kHz PWM duty cycle). The last three selections place the chip into a test mode and should not be used. DR2 DR1 DR0 DESCRIPTION 0 0 0 1/16 0 0 1 1/8 0 1 0 1/4 0 1 1 1/2 10 0 1 1 0 1 Test Mode 1 1 1 0 Test Mode 2 1 1 1 Test Mode 3 Bit 17: Fail-Safe Latch Clear (FSCLR) When FSCLR bit is set to one, the internal fail-safe timer is reset to 0, and the fail-safe latches are reset. FSCLR is automatically reset to 0 when CS goes high. FSCLR DESCRIPTION 0 No Action 1 Reset Fail-Safe Timer and Latches Bits 18 to 20: Timeout Period Select (TO0 to TO2) TO2, TO1 and TO0 select the desired fail-safe timeout period,tOUT. On power-up, the default timeout is 5 minutes. TO2 TO1 TO0 TIMEOUT (MINUTES) 00 0 5 00 1 10 01 0 20 01 1 40 10 0 80 1 0 1 160 1 1 0 320 1 1 1 Indefinite (No Timeout) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |