23 / 33 page ![]() ( ) ( ) 0.25 C Accuracy = 1.8 V 3.3 V 0.375 C V PSR ° é ù ± - ´ = ± ° ê ú ë û ( ) ( ) 0.25 C Accuracy V+ 3.3 V V PSR ° é ù = ± - ´ ê ú ë û 0.8 0.6 0.4 0.2 0 -0.2 0.4 0.6 - - Temperature ( C) ° Slope1 MAX Slope2 MAX Slope3 MAX Calibration at 25°C Removes Offset -40 -20 0 40 60 130 100 110 120 80 90 70 50 20 30 10 -30 -10 TMP112-Q1 www.ti.com SLOS887D – SEPTEMBER 2014 – REVISED DECEMBER 2015 Application Information (continued) 8.1.2 Using The Slope Specifications With a 1-Point Calibration The initial accuracy assurance at 25°C with the slope regions provides an accuracy that is high enough for most applications. However, if higher accuracy is desired, this increase can be achieved with a 1-point calibration at 25°C. This calibration removes the offset at room temperature, thereby reducing the source of error in a TMP112-Q1 temperature reading down to the curvature. Figure 18 shows the error of a calibrated TMP112-Q1 device. Figure 18. Calibrated Accuracy and Slope Curves versus Temperature Using the previous example temperature range of 0°C to 50°C, the worst-case temperature error is now reduced to the worst-case slopes because the offset at 25°C (that is, the maximum and minimum temperature errors of 0.3°C and –0.5°C) is removed. Therefore, a user can expect the worst-case accuracy to improve to 0.175°C. 8.1.2.1 Power Supply-Level Contribution to Accuracy The superior accuracy that can be achieved with the TMP112-Q1 device is complemented by the immunity-to- DC variations from a 3.3-V supply voltage. This immunity is important because it spares the user from having to use another LDO regulator to produce 3.3 V to achieve accuracy. Nevertheless, the noise quantization that results from changing supply can add some slight change in temperature measurement accuracy. As an example, if the user chooses to operate the device at 1.8 V, the worst-case expected change in accuracy can be calculated with Equation 14: (14) (15) This example is a worst-case accuracy contribution as a result of variation in power supply that must be added to the accuracy plus the slope maximum. Copyright © 2014–2015, Texas Instruments Incorporated Submit Documentation Feedback 23 Product Folder Links: TMP112-Q1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |