| Electronic Components Datasheet Search |
|
LMP90077MHX Datasheet(PDF) 29 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LMP90077MHX Datasheet(HTML) 29 Page - Texas Instruments |
|
29 / 70 page ![]() 29 LMP90077, LMP90078, LMP90079, LMP90080 www.ti.com SNAS521H – JULY 2011 – REVISED JANUARY 2016 Product Folder Links: LMP90077 LMP90078 LMP90079 LMP90080 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated 9.4 Device Functional Modes 9.4.1 Channels Scan Mode There are four scan modes. These scan modes are selected using the CH_SCAN: CH_SCAN_SEL bit. The first scanned channel is FIRST_CH, and the last scanned channel is LAST_CH; they are both located in the CH_SCAN register. The CH_SCAN register is double buffered. That is, user inputs are stored in a slave buffer until the start of the next conversion during which time they are transferred to the master buffer. Once the slave buffer is written, subsequent updates are disregarded until a transfer to the master buffer happens. Hence, it may be appropriate to check the CH_SCAN_NRDY bit before programming the CH_SCAN register. 9.4.1.1 ScanMode0: Single-Channel Continuous Conversion LMP900xx continuously converts the selected FIRST_CH. Do not operate in this scan mode if gain ≥ 16 and the LMP900xx is running in background calibration modes BgcalMode1 or BgcalMode2. If this is the case, then it is more suitable to operate the device in ScanMode2 instead. 9.4.1.2 ScanMode1: Multiple-Channels Single Scan LMP900xx converts one or more channels starting from FIRST_CH to LAST_CH, and then enters the stand-by state. 9.4.1.3 ScanMode2: Multiple-Channels Continuous Scan LMP900xx continuously converts one or more channels starting from FIRST_CH to LAST_CH, and then it repeats this process. 9.4.1.4 ScanMode3: Multiple-Channels Continuous Scan with Burnout Currents This mode is the same as ScanMode2 except that the burnout current is provided in a serially scanned fashion (injected in a channel after it has undergone a conversion). Thus it avoids burnout current injection from interfering with the conversion result for the channel. The sensor diagnostic burnout currents are available for all four scan modes. The burnout current is further gated by the BURNOUT_EN bit for each channel. ScanMode3 is the only mode that scans multiple channels while injecting burnout currents without interfering with the signal. This is described in details in Burnout Currents. 9.4.2 Sensor Interface The LMP90080/LMP90078 contains two excitation currents (IB1 & IB2) for sourcing external sensors, and the LMP900xx contain two burnout currents for sensor diagnostics. They are described in the next sections. 9.4.2.1 IB1 & IB2 - Excitation Currents (LMP90080/LMP90078) IB1 and IB2 can be used for providing currents to external sensors, such as RTDs or bridge sensors. 100µA to 1000µA, in steps of 100µA, can be sourced by programming the ADC_AUXCN: RTD_CUR_SEL bits. Refer to 3–Wire RTD to see how IB1 and IB2 can be used to source a 3-wire RTD. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |