| Electronic Components Datasheet Search |
|
LMP90077MHX Datasheet(PDF) 33 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LMP90077MHX Datasheet(HTML) 33 Page - Texas Instruments |
|
33 / 70 page ![]() R/WB = Read/Write Data 0: Write Data 1: Read Data 7 [3:0] [N:0] R/WB SZ SZ = Size 0x0: 1 byte 0x1: 2 bytes 0x2: 3 bytes 0x3: Streaming ± 3+ bytes until CSB is de-asserted [6:5] 4 0 Lower Register Address (LRA) Data Byte (s) Instruction Byte 2 (INST2) Data Byte (s) [7:0] [7:3] [2:0] 0x0 Upper Register Address (URA) Instruction Byte 1 (INST1) Upper Address Byte (UAB) R/WB = Read/Write Address 0x10: Write Address 0x90: Read Address RA/WAB Transaction 2 ± Data Access Transaction 1 ± URA Setup ± necessary only when the previous URA is different than the desired URA. 33 LMP90077, LMP90078, LMP90079, LMP90080 www.ti.com SNAS521H – JULY 2011 – REVISED JANUARY 2016 Product Folder Links: LMP90077 LMP90078 LMP90079 LMP90080 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated 9.5.1.2 Register Read/Write Protocol Figure 55 shows the protocol how to write to or read from a register. Transaction 1 sets up the upper register address (URA) where the user wants to start the register-write or register-read. Transaction 2 sets the lower register address (LRA) and includes the Data Byte(s), which contains the incoming data from the master or outgoing data from the LMP900xx. Examples of register-reads or register-writes can be found in Register Read/Write Examples. Figure 55. Register Read/Write Protocol 9.5.1.3 Streaming When writing/reading 3+ bytes, the user must operate the device in Normal Streaming mode or Controlled Streaming mode. In the Normal Streaming mode, which is the default mode, data runs continuously starting from ADDR until CSB deasserts. This mode is especially useful when programming all the configuration registers in a single transaction. See the Normal Streaming Example section for an example of the Normal Streaming mode. In the Controlled Streaming mode, data runs continuously starting from ADDR until the data has run through all (STRM_RANGE + 1) registers. For example, if the starting ADDR is 0x1C, STRM_RANGE = 5, then data will be written to or read from the following ADDRs: 0x1C, 0x1D, 0x1E, 0x1F, 0x20, 0x21. Once the data reaches ADDR 0x21, LMP900xx will wrap back to ADDR 0x1C and repeat this process until CSB deasserts. See the Controlled Streaming Example section for an example of the Controlled Streaming mode. If streaming reaches ADDR 0x7F, then it will wrap back to ADDR 0x00. Furthermore, reading back the Upper Register Address after streaming will report the Upper Register Address at the start of streaming, not the Upper Register Address at the end of streaming. To stream, write 0x3 to INST2’s SZ bits as seen in Figure 55. To select the stream type, program the SPI_STREAMCN: STRM_TYPE bit. The STRM_RANGE can also be programmed in the same register. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |