Electronic Components Datasheet Search
  English  ▼

X  

LMP90077MHX Datasheet(PDF) 11 Page - Texas Instruments

Part # LMP90077MHX
Description  Sensor AFE System: Multi-Channel, Low-Power 16-Bit Sensor AFE
PDF  70 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

LMP90077MHX Datasheet(HTML) 11 Page - Texas Instruments

Back Button LMP90077MHX Datasheet HTML 7Page - Texas Instruments LMP90077MHX Datasheet HTML 8Page - Texas Instruments LMP90077MHX Datasheet HTML 9Page - Texas Instruments LMP90077MHX Datasheet HTML 10Page - Texas Instruments LMP90077MHX Datasheet HTML 11Page - Texas Instruments LMP90077MHX Datasheet HTML 12Page - Texas Instruments LMP90077MHX Datasheet HTML 13Page - Texas Instruments LMP90077MHX Datasheet HTML 14Page - Texas Instruments LMP90077MHX Datasheet HTML 15Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 70 page
background image
11
LMP90077, LMP90078, LMP90079, LMP90080
www.ti.com
SNAS521H – JULY 2011 – REVISED JANUARY 2016
Product Folder Links: LMP90077 LMP90078 LMP90079 LMP90080
Submit Documentation Feedback
Copyright © 2011–2016, Texas Instruments Incorporated
8.6 Timing Requirements
Unless otherwise noted, specified limits apply for VA = VIO = 3 V. The typical values apply for TA = 25°C.
MIN
NOM
MAX
UNIT
fSCLK
See Figure 1.
10
MHz
tCH
SCLK High time
0.4 / fSCLK
ns
tCL
SCLK Low time
0.4 / fSCLK
ns
8.7 Timing Requirements - CSB Timing
MIN
NOM
MAX
UNIT
tCSSU
CSB Setup time prior to an SCLK
rising edge
See Figure 2.
5
ns
tCSH
CSB Hold time after the last rising
edge of SCLK
See Figure 3.
6
ns
8.8 Timing Requirements - SCLK and SDI Timing
MIN
NOM
MAX
UNIT
tCLKR
SCLK Rise time
See Figure 4.
1.15
ns
tCLKF
SCLK Fall time
1.15
ns
tDISU
SDI Setup time prior to an SCLK rising
edge
See Figure 5.
5
ns
tDIH
SDI Hold time after an SCLK rising
edge
6
ns
8.9 Timing Requirements - SDO Timing With DOD1
MIN
NOM
MAX
UNIT
tDOA
SDO Access time after an SCLK falling edge
See Figure 6.
35
ns
tDOH
SDO Hold time after an SCLK falling edge
5
ns
tDOD1
SDO Disable time after the rising edge of CSB
See Figure 7.
27
ns
8.10 Timing Requirements - SDO Timing with DOD2
MIN
NOM
MAX
UNIT
tDOD2
SDO Disable time after either edge of SCLK
See Figure 8 and Figure 9.
27
ns
(1)
This parameter is specified by design and/or characterization and is not tested in production.
8.11 Timing Requirements - SDO and DRDYB Timing
MIN
NOM
MAX
UNIT
tDOE
SDO Enable time from the falling
edge of the 8th SCLK
See Figure 10.
35
ns
tDOR
SDO Rise time(1)
See Figure 11.
7
ns
tDOF
SDO Fall time(1)
7
ns
tDRDYB
Data Ready Bar pulse at every
1/ODR second
ODR
≤ 13.42 SPS
64
µs
13.42 < ODR
≤ 214.65 SPS
4
µs



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com