Back Button TTP239 Datasheet HTML 3Page - Tontek Design Technology TTP239 Datasheet HTML 4Page - Tontek Design Technology TTP239 Datasheet HTML 5Page - Tontek Design Technology TTP239 Datasheet HTML 6Page - Tontek Design Technology TTP239 Datasheet HTML 7Page - Tontek Design Technology TTP239 Datasheet HTML 8Page - Tontek Design Technology TTP239 Datasheet HTML 9Page - Tontek Design Technology TTP239 Datasheet HTML 10Page - Tontek Design Technology TTP239 Datasheet HTML 11Page - Tontek Design Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 16 page
background image
TTP239
2016/3/7
Page 7 of 16
Version:1.1
Ⅲ
. Key operating mode(By SM pad option)
The TTP239 has the Single-key and Multi-key functions by SM pad option
SM
Option features
Remark
1
Multi-key mode
Default
0
Single key mode
Multi-key mode:The TP0-TP7 can be detected 2 keys or above 2 keys at the same time
Single-key mode:The TP0-TP7 can be detected 1 key only at the same time, when any key be
detected, the other 7 keys can not be detected
Ⅳ
. Maximum key on duration time(By MOT1、MOT0 pad option)
If some objects cover in the sense pad, and causing the change quantity enough to be detected.
To prevent this, the TTP239 sets a timer to monitor the detection. The timer is the maximum on
duration time. When the detection is over the timer, the system will return to the power-on initial
state, and the output becomes inactive until the next detection
MOT1
MOT0
Option features
Remark
0
0
Maximum on time 120 sec
0
1
Maximum on time 64 sec
1
0
Maximum on time 16 sec
1
1
Infinite(Disable maximum on time)
Default
Ⅴ
. Fast and Low power mode select(By LPM pad option)
The TTP239 has Fast mode and Low Power mode to be selected. It depends on the state of
LPM pad. When the LPM pin is connected to VSS, the TTP239 runs in Fast mode. When the
LPM pin is opened or connected to VDD, the TTP239 runs in Low Power mode.
In the Fast mode response time is faster, but the current consumption will be increased. In the
Low Power mode it will be saving power, but will be slowing response time for first touch. When
it awaked in fast mode, the response time is the same the fast mode. In this mode when
detecting key touch, it will switch to Fast mode. Until the key touch is released and will keep a
time about 8sec. Then it returns to Low Power mode.
The states and timing of two modes please see below figure.
Low Power Mode timing diagram:
Response time
Release time
Stand-by timing
False Trigger
Valid Trigger
KEY TOUCH
TP(i)
TPQ(i)
KEY RELEASE
Trigger
Finger
~125ms
ABOUT 8SEC
~16ms
~125ms
~16ms
~125ms
Stand-by timing
Touch operation timing
Touch operation timing
Stand-by timing



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com