15 / 38 page ![]() LM64 www.ti.com SNAS207A – MAY 2004 – REVISED MARCH 2013 DIODE FAULT DETECTION The LM64 can detect fault conditions caused by the remote diode. If the D+ pin is detected to be shorted to VDD, or open: (1) the Remote Temperature High Byte (RTHB) register is loaded with 127°C, (2) the Remote Temperature Low Byte (RTLB) register is loaded with 0, and (3) the OPEN bit (D2) in the status register is set. Therefore, if the Remote T_CRIT setpoint register (RCS): (1) is set to a value less than +127°C and (2) the ALERT Mask is disabled, then the ALERT output pin will be pulled low. If the Remote High Setpoint High Byte (RHSHB) is set to a value less than +127°C and (2) the ALERT Mask is disabled, then the ALERT and T_Crit outputs will be pulled low. The OPEN bit by itself will not trigger an ALERT. If the D+ pin is shorted to either ground or D −, then the Remote Temperature High Byte (RTHB) register is loaded with −128°C (1000 0000) and the OPEN bit in the ALERT Status Register will not be set. A temperature reading of −128°C indicates that D+ is shorted to either ground or D-. If the value in the Remote Low Setpoint High Byte (RLSHB) Register is more than −128°C and the ALERT Mask is Disabled, ALERT will be pulled low. COMMUNICATING WITH THE LM64 Each data register in the LM64 falls into one of four types of user accessibility: 1. Read Only 2. Write Only 3. Read/Write same address 4. Read/Write different address A Write to the LM64 is comprised of an address byte and a command byte. A write to any register requires one data byte. Reading the LM64 Registers can take place after the requisite register setup sequence takes place. See LM64 Required Initial Fan Control Register Sequence. The data byte has the Most Significant Bit (MSB) first. At the end of a read, the LM64 can accept either Acknowledge or No-Acknowledge from the Master. Note that the No-Acknowledge is typically used as a signal for the slave indicating that the Master has read its last byte. DIGITAL FILTER The LM64 incorporates a user-configured digital filter to suppress erroneous Remote Temperature readings due to noise. The filter is accessed in the Remote Diode Temperature Filter and Comparator Mode Register. The filter can be set according to the following table. Level 2 is maximum filtering. Table 4. Digital Filter Selection Table D2 D1 Filter 0 0 No Filter 0 1 Level 1 1 0 Level 1 1 1 Level 2 Copyright © 2004–2013, Texas Instruments Incorporated Submit Documentation Feedback 15 Product Folder Links: LM64 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |