26 / 54 page ![]() ASX340AT www.onsemi.com 26 TABLE 21. PATCH LOADER HOST COMMANDS Patch Loader Host Command Value Type Description Load Patch 0x8700 Asynchronous Load a patch from SPI Flash and automatically apply Status 0x8701 Synchronous Get status of an active Load Patch or Apply Patch request Apply Patch 0x8702 Asynchronous Apply a patch (already located in Patch RAM) Reserve RAM 0x8706 Synchronous Reserve RAM to contain a patch TABLE 22. MISCELLANEOUS HOST COMMANDS Miscellaneous Host Command Value Type Description Invoke Command Seq 0x8900 Synchronous Invoke a sequence of commands stored in NVM Config Command Seq Processor 0x8901 Synchronous Configures the Command Sequencer processor Wait For Event 0x8902 Synchronous Wait for a system event to be signalled TABLE 23. CALIBRATION STATS HOST COMMANDS Calibration Stats Host Command Value Type Description Control 0x8B00 Asynchronous Start statistics gathering Read 0x8B01 Synchronous Read the results back SLAVE TWO-WIRE SERIAL INTERFACE The two-wire serial interface bus enables read/write access to control and status registers within the ASX340AT. This interface is designed to be compatible with the MIPI Alliance Standard for Camera Serial Interface 2 (CSI-2) 1.0, which uses the electrical characteristics and transfer protocols of the two-wire serial interface specification. The interface protocol uses a master/slave model in which a master controls one or more slave devices. The sensor acts as a slave device. The master generates a clock (SCLK) that is an input to the sensor and used to synchronize transfers. Data is transferred between the master and the slave on a bidirectional signal (SDATA). SDATA is pulled up to VDD_IO off-chip by a pull-up resistor in the range of 1.5 to 4.7 k Ω. Protocol Data transfers on the two-wire serial interface bus are performed by a sequence of low-level protocol elements, as follows: • a start or restart condition • a slave address/data direction byte • a 16-bit register address • an acknowledge or a no-acknowledge bit • data bytes • a stop condition The bus is idle when both SCLK and SDATA are HIGH. Control of the bus is initiated with a start condition, and the bus is released with a stop condition. Only the master can generate the start and stop conditions. The SADDR pin is used to select between two different addresses in case of conflict with another device. If SADDR is LOW, the slave address is 0 x 90; if SADDR is HIGH, the slave address is 0 x BA. See Table 21. TABLE 24. TWO-WIRE INTERFACE ID ADDRESS SWITCHING SADDR Two-Wire Interface Address ID 0 0x90 1 0xBA Start Condition A start condition is defined as a HIGH-to-LOW transition on SDATA while SCLK is HIGH. At the end of a transfer, the master can generate a start condition without previously generating a stop condition; this is known as a “repeated start” or “restart” condition. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |