| Electronic Components Datasheet Search |
|
TLE7233EM Datasheet(PDF) 21 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE7233EM Datasheet(HTML) 21 Page - Infineon Technologies AG |
|
21 / 33 page ![]() Data Sheet 21 Rev. 1.2, 2014-05-09 SPI Driver for Enhanced Relay Control SPIDER - TLE7233EM Diagnostic Features 8 Diagnostic Features The SPI of TLE7233EM provides diagnosis information about the device and about the load. The diagnosis information of the protective functions of channel n is latched in the diagnosis flag Dn. The open load diagnosis of channel n is latched in the diagnosis flag OLn. Both flags are cleared by INn =00B which disables the diagnosis current ID(PD) (a small pull down current) as well. Following table shows possible failure modes and the according protective and diagnostic action. j 8.1 Open Load Diagnosis timing The TLE7233EM offers an open load diagnosis for each channel in OFF mode. The time td(OL) is applied to filter short time events. Figure 9 Open Load timing Failure Mode Comment Open Load or short circuit to GND Diagnosis, when channel n is switched on: INn = 01B: if input pin is high: none INn = 10B: none Diagnosis, when channel n is switched off: INn = 00B: none, diagnosis flags are cleared and the diagnosis current is switched off INn = 01B: if input pin is low, according to voltage at the output pin, the flag OLn is set after time td(OL) INn = 11B: according to voltage level at the output pin, the flag OLn is set after time td(OL) Over temperature When over temperature occurs, the affected channel n is switched off. The according diagnosis flag Dn is set. The diagnosis flags are latched until they have been cleared by INn = 00B. The over temperature detection is active in ON-state as well as OFF-state. Over Load (Short Circuit) When over load is detected at channel n, the affected channel is switched off after time tOFF(OVL) and the dedicated diagnosis flag Dn is set. The diagnosis flags are latched until they have been cleared by INn = 00B. OpenLoad.emf IN VDS t t td(OL) OLn = 1b Open Load occures here IN VDS t t td(OL) OLn = 1b VDS(OL) Open Load occures here VDS(OL) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |