| Electronic Components Datasheet Search |
|
TAS5110DAD Datasheet(PDF) 8 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS5110DAD Datasheet(HTML) 8 Page - Texas Instruments |
|
8 / 20 page ![]() TAS5110 SLES028A – MAY 2002 – REVISED SEPTEMBER 2002 8 www.ti.com H-bridge output mapping (continued) The B-side half-bridge output is designed to the following truth table: INPUTS OUTPUTS DESCRIPTION RESET PWDN PWM_BP PWM_BM SHUTDOWN OUTPUTB DESCRIPTION X X X X 0 0 or Hi-Z† Shutdown X 0 X X 1 Hi-Z Powerdown 0 1 X X 1 0 Reset 1 1 0 0 0 0 Shutdown 1 1 0 1 1 0 Normal 1 1 1 0 1 1 Normal 1 1 1 1 0 0 Shutdown † Output is 0 for low voltage, over temperature, or illegal input. Hi-Z is for over current. control/sense circuitry The control/sense circuitry consists of the following 3.3-V logic level pins: PWDN, RESET, ERR0, ERR1, and SHUTDOWN. The active-low PWDN input pin powers down all internal circuitry and forces the H-bridge outputs to the Hi-Z state. When the PWDN pin is low, the open drain ERR0, ERR1, and SHUTDOWN pins are also disabled so that their outputs can be pulled high. The active-low RESET input pin forces the H-bridge outputs to the low-low state and resets the over-current shutdown latch. The PWDN pin overrides the RESET pin. The ERR0, ERR1, and SHUTDOWN outputs indicate the following conditions in the TAS5110 as shown in the table below. These three outputs are open-drain connections with internal pullup resistors so that wire-ORed connections can be made by the user with other external control devices. The short-circuit protect error condition latches the TAS5110 in this shutdown state and forces the H-bridge outputs to the Hi-Z state until the device is reset by means of the RESET pin. The illegal PWM input state, over-temperature, and low regulator voltage error conditions does not latch the device in the shutdown condition. Instead the H-bridge outputs are forced to the low-low state and the TAS5110 returns to normal operation as soon as the error condition ends. Loss of clocking PWM signal is also considered an illegal PWM input state. SHUTDOWN ERR1 ERR0 FUNCTION OUTPUTA OUTPUTB 0 0 0 Illegal PWM input state Low Low 0 0 1 Short circuit protect (latch) Hi-Z Hi-Z 0 1 0 Over temperature protect Low Low 0 1 1 Low regulator voltage protect Low Low 1 0 0 Reserved — — 1 0 1 Reserved — — 1 1 0 High temperature – warning Normal Normal 1 1 1 Normal operation Normal Normal |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |