  RT2660 Datasheet HTML 1Page - Richtek Technology Corporation RT2660 Datasheet HTML 2Page - Richtek Technology Corporation RT2660 Datasheet HTML 3Page - Richtek Technology Corporation RT2660 Datasheet HTML 4Page - Richtek Technology Corporation RT2660 Datasheet HTML 5Page - Richtek Technology Corporation RT2660 Datasheet HTML 6Page - Richtek Technology Corporation RT2660 Datasheet HTML 7Page - Richtek Technology Corporation RT2660 Datasheet HTML 8Page - Richtek Technology Corporation RT2660 Datasheet HTML 9Page - Richtek Technology Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 18 page
background image
5
RT2660
DS2660-00
September 2015
www.richtek.com
©
Copyright 2015 Richtek Technology Corporation. All rights reserved.
is a registered trademark of Richtek Technology Corporation.
Power Good
The RT2660 has one open-drain power good (PGOOD)
pin. The PGOOD pin de-asserts as soon as the EN pin is
pulled low or an under-voltage condition on V5IN or any
other fault is detected.
Output Over-Voltage Protection (OVP)
In addition to the power good function described above,
the RT2660 has additional OVP and UVP thresholds and
protection circuits.
An OVP condition is detected when the output voltage is
approximately 120% x VREFIN. In this case, the converter
de-asserts the PGOOD signals and performs the over-
voltage protection function. During OVP, the low-side
MOSFET is always on before triggering a negative over-
current. When a negative OC is also tripped, the low-side
MOSFET is no longer continuously on, and pulsed signals
are generated to limit the negative inductor current.
For RT2660L OVP latch mode, when the VOUT pin voltage
drops below 400mV, the low-side MOSFET is turned off
and the converter latches off. The converter remains in
the off state until the device is reset by cycling 5V until
the 5V POR is reached or when the EN pin is toggled off
and on.
For RT2660H OVP non-latch, when the VOUT pin voltage
drops below 400mV, the low-side MOSFET is turned off
(non-latch), recovery until the VOUT pin voltage exceeds
400mV again.
Output Under-Voltage Protection (UVP)
Output under-voltage protection works in conjunction with
the current protection described in the over-current
protection and over-current limit sections. If the output
voltage drops below 68% of VREFIN, after approximately a
256
μs delay, the device stops switching and enters UVP.
For RT2660L UVP latch mode, the device stop switching
and enter latch mode. The converter remain in the off state
until the device is reset by VIN or EN.
For RT2660H UVP hiccup mode, the device stops
switching and enters hiccup mode. After a hiccup waiting
time, a re-start is attempted. If the fault condition is not
cleared, hiccup mode operation may continue indefinitely.
Over-Current Protection (OCP)
Both positive and negative over-current protection are
provided in the RT2660 :
Over-Current Limit (OCL)
RT2660 has cycle-by-cycle over current limiting
protection. The inductor current is monitored during the
low-side MOSFET turning on. When the inductor current
is larger than the over current trip level, the high-side
MOSFET turns off until the current drops below the OCL
limit. Because RT2660 uses a valley current limiting
scheme, the average output current limit calculation is
valley OCL trip level plus half of the inductor ripple
current.
Negative OCL
The negative OCL circuit acts when the converter is
sinking current from the output capacitor(s). The
converter continues to act in a valley mode, the absolute
value of the negative OCL set point is typically
−9.3A or
−7.3A (depending on mode selection).
Over-Temperature Protection (OTP)
The RT2660 has an over-temperature protection. When
the device triggers the OTP, the device shuts down. Until
the temperature drops below the low temperature
threshold, the OTP relieves and the device re-soft starts.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com