40 / 60 page ![]() Page 40 OXCF950 DATA SHEET V1.1 OXFORD SEMICONDUCTOR LTD. Designers have the option of using either TTL clock modules or crystal oscillator circuits for system clock input, with minimal additional components. The following two sections describe how each can be connected. 6.10.5 TTL Clock Module Using a TTL module for the system clock simply requires the module to be supplied with +5v power and GND connections. The clock output can then be connected directly to XTLI. XTLO should be left unconnected. CLOCK XTLI VDD Figure 5: TTL Clock Module Connectivity 6.10.6 External 1x Clock Mode The transmitter and receiver can accept an external clock applied to the RI# and DSR# pins respectively. The clock options are selected using the clock select register (CKS - see section 6.11.8). The transmitter and receiver may be configured to operate in 1x (Isochronous) mode by setting CKS[7] and CKS[3], respectively. In Isochronous mode, transmitter or receiver will use the 1x clock (usually but not necessarily an external source) where asynchronous framing is maintained using start, parity and stop-bits. However serial transmission and reception is synchronised to the 1x clock. In this mode asynchronous data may be transmitted at baud rates up to 60Mbps. The local 1x clock source can be asserted on the DTR# pin. Note that line drivers need to be capable of transmission at data rates twice the system clock used (as one cycle of the system clock corresponds to 1 bit of serial data). Also note that enabling modem interrupts is illegal in isochronous mode, as the clock signal will cause a continuous change to the modem status (unless masked in MDM register, see section 6.11.10). 6.10.7 Crystal Oscillator Circuit The OXCF950 may be clocked by a crystal connected to XTLI and XTLO or directly from a clock source connected to the XTLI pin. The circuit required to use the on-chip oscillator is shown opposite. R1 R2 C1 C2 XTLI XTLO Figure 6: Crystal Oscillator Circuit Frequency Range (MHz) C1 (pF) C2 (pF) R1 ( Ω Ω) R2 ( Ω Ω) 1.8432 – 8 68 22 220K 470R 8-60 33-68 33 – 68 220K-2M2 470R Table 36: Component Values Note: For better stability use a smaller value of R1. Increase R1to reduce power consumption. The total capacitive load (C1 in series with C2) should be that specified by the crystal manufacturer (nominally 16pF) 6.11 Additional Features 6.11.1 Additional Status Register ‘ASR’ ASR[0]: Transmitter disabled logic 0 ⇒ The transmitter is not disabled by in-band flow control. logic 1 ⇒ The receiver has detected an XOFF, and has disabled the transmitter. This bit is cleared after a hardware reset or channel software reset. The software driver may write a 0 to this bit to re-enable the transmitter if it was disabled by in-band flow control. Writing a 1 to this bit has no effect. ASR[1]: Remote transmitter disabled logic 0 ⇒ The remote transmitter is not disabled by in- band flow control. logic 1 ⇒ The transmitter has sent an XOFF character, to disable the remote transmitter. (Cleared when a subsequent XON is sent). This bit is cleared after a hardware reset or chann el software reset. The software driver may write a 0 to this bit to re-enable the remote transmitter (an XON is transmitted). Writing a 1 to this bit has no effect. Note : The remaining bits (ASR[7:2]) of this register are read only ASR[2]: RTS This is the complement of the actual state of the RTS# pin when the device is not in loopback mode. The driver software can determine if the remote transmitter is disabled by RTS# out-of-band flow control by reading this bit. In |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |