Back Button SC84502AP Datasheet HTML 5Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 6Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 7Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 8Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 9Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 10Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 11Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 12Page - Silan Microelectronics Joint-stock SC84502AP Datasheet HTML 13Page - Silan Microelectronics Joint-stock Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 14 page
background image
Silan
Semiconductors
SC84502
HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTD
Rev: 1.0
2000.12.31
9
c). Set Default (F6)
The command reinitializes all conditions to the power-on defaults.
d). Disable (F5)
This command is used in the stream mode to stop transmissions from SC84502.
e). Enable (F4)
Begins transmissions, if in stream mode.
f). Set Sampling Rate (F3, XX)
In the stream mode, this command sets the sampling rate to the value indicated by byte hex XX, shown in
following:
Second byte XX
Sample Rate
0A
10/sec
14
20/sec
28
40/sec
3C
60/sec
50
80/sec
64
100/sec
C8
200/sec
g). Read Device Type (F2)
SC84502 always echoes “FA, 00 “ following this command.
h). Set Remote Mode (F0)
Data values are reported only in response to a Read Data command.
i). Set Wrap Mode (EE)
Wrap mode remains until Reset (FF) or Reset Wrap Mode (EC) is received.
j). Reset Wrap Mode (EC)
SC84502 returns to the previous mode of operation after receiving this command.
k). Read Data (EB)
This command is executed in either remote or stream mode. The data is transmitted even if there has been
no movement since the last report or the button status is unchanged. Following a Read Data command, the
registers are cleared after a data transmission.
l). Set Stream Mode (EA)
This command sets SC84502 in stream mode.
m). Status Request (E9)
When this command is issued by the system, SC84502 respond with a 3-byte status report as follows:



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com