Back Button ATPL00B Datasheet HTML 116Page - ATMEL Corporation ATPL00B Datasheet HTML 117Page - ATMEL Corporation ATPL00B Datasheet HTML 118Page - ATMEL Corporation ATPL00B Datasheet HTML 119Page - ATMEL Corporation ATPL00B Datasheet HTML 120Page - ATMEL Corporation ATPL00B Datasheet HTML 121Page - ATMEL Corporation ATPL00B Datasheet HTML 122Page - ATMEL Corporation ATPL00B Datasheet HTML 123Page - ATMEL Corporation ATPL00B Datasheet HTML 124Page - ATMEL Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 120 / 152 page
background image
Atmel ATPL00B [datasheet]
43028A-ATPL - 9/12
120
11.1
Frequency coding
Logic symbol „1‟ is sent using a frequency value slightly below Fcarrier while the upper side is used to represent the
logic symbol „0‟, according to:
•
F(“1”) = Fcarrier - baud rate/2
•
F(“0”) = Fcarrier + baud rate /2
Besides there is another option, where you can choose (frequency deviation=0.5):
•
F(“1”) = Fcarrier - baud rate/4
•
F(“0”) = Fcarrier + baud rate/4
Exact frequencies for every baud rate can be found in 0.
Note: 0.5 deviation value is not allowed when working at Baud Rate = 600. See Table 11-2 for suitable values.
Table 11-2.
Allowed deviation values by baud rate
Baud rate
F (Hz)
Deviation
600
(1)
--
600
--
1
1200
600
1200
0.5
1
2400
(2)
1200
2400
(2)
0.5
1
4800
2400
4800
0.5
1
Note:
1.Deviation value = 0.5 not allowed
Note:
2.Default value
A couple of modems have been implemented inside ATPL00B (each one with Tx and Rx capabilities), so we can select
between them to establish different values or frequency deviation for transmission and reception (See DEV_TX and
DEV_RX fields in CONFIG register).
This allows the device to be configured to comply with KONNEX requirements, setting a deviation value = 1 for
reception and a deviation value = 0.5 for transmission.
Table 11-3.
Allowed Tx-Rx deviation values
Tx
Rx
(1)0.5
(1)0.5
0.5
1
1
1
Note:
1. If a reception deviation value = 0.5 is selected, same transmission deviation value = 0.5 must be selected as
well. In this case, only baud rate=2400bauds can be used



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com