Back Button MP2110 Datasheet HTML 6Page - Monolithic Power Systems MP2110 Datasheet HTML 7Page - Monolithic Power Systems MP2110 Datasheet HTML 8Page - Monolithic Power Systems MP2110 Datasheet HTML 9Page - Monolithic Power Systems MP2110 Datasheet HTML 10Page - Monolithic Power Systems MP2110 Datasheet HTML 11Page - Monolithic Power Systems MP2110 Datasheet HTML 12Page - Monolithic Power Systems MP2110 Datasheet HTML 13Page - Monolithic Power Systems MP2110 Datasheet HTML 14Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 15 page
background image
MP2110 – 3A SYNCHRONOUS BUCK CONVERTER WITH INPUT CURRENT LIMIT
MP2110 Rev. 1.11
www.MonolithicPower.com
10
9/26/2014
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2014 MPS. All Rights Reserved.
OPERATION
The MP2110 is a high efficiency, 1.5MHz,
synchronous step-down converter with input
current limit switch. The MP2110 is optimized for
low voltage, USB port and Li-Ion battery powered
applications where high efficiency and small size
are critical. The MP2110 can achieve 100% duty
cycle.
MP2110 uses constant on-time control with input
voltage feed forward to stabilize the switching
frequency over full input range. At light load,
MP2110 employs a proprietary control of low side
switch and inductor current to eliminate ringing
on switching node and improve efficiency.
Constant On-time Control
Compare to fixed frequency PWM control,
constant on-time control offers the advantage of
simpler control loop and faster transient response.
By using input voltage feed forward, MP2110
maintains a nearly constant switching frequency
across input and output voltage range. The on-
time of the switching pulse can be estimated as:
OUT
ON
IN
V
T
0.722 s
V
=⋅
μ
To prevent inductor current run away during load
transient, MP2110 fixes the minimum off time to
be 60ns. However, this minimum off time limit will
not affect operation of MP2110 in steady state.
Light Load Operation
In
light
load condition,
MP2110
uses
a
proprietary control scheme to save power and
improve efficiency. Instead of turning off the low
side switch immediately when inductor current
start to reverse, MP2110 gradually ramp down
and regulates the low side switch current to a
minimal level, thus avoids the ringing at switching
node that always occurs in discontinuous
conduction mode (DCM) operation.
Current Limit
MP2110 has a typical 5A current limit for the high
side switch. When the high side switch hits
current limit, the high side switch will turn off, and
low side switch will turn on until the inductor
current decreases to the valley current limit. This
will prevent inductor current from continuing to
build up which will result in damage of the
components.
Short Circuit Protection
MP2110 enters short circuit protection mode after
the inductor current hits the current limit and lasts
for 100μs, and tries to recover from short circuit
with hiccup mode. In short circuit protection,
MP2110 will disable output power stage,
discharge soft-start cap and then automatically
try to soft-start again. If the short circuit condition
still holds, MP2110 repeats this operation cycle
till short circuit disappears and output rises back
to regulation level.
Programmable Input Current Limit
The MP2110 has an input current limit protection
function. It will insure that the input current
doesn't exceed the maximum value, when the
input is supplied by the USB. Once the input
current triggers the set current limit level, the
output current will hold at the current limit until
thermal shutdown.
The current limit can be estimated as:
() ()
()
6
LIM
SET
0.96x4
IA
Rk
=
Ω
The input current limit resistor value can be found
from Table 1.
Notes:
6) The formula is theoretic. Refer to table 1 for accurate current
limit setting.
Table 1—Resistor vs. Current Limit Setting
ILIMIT (A)
RSET (kΩ)
0.39
13.3
0.6
7.15
0.81
5.1
1.05
3.92
1.15
3.48
1.52
2.4
1.85
1.96
2.05
1.74
2.25
1.58
2.57
1.37
2.83
1.24
3.08
1.13



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com