| Electronic Components Datasheet Search |
|
LTC4121 Datasheet(PDF) 16 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4121 Datasheet(HTML) 16 Page - Linear Technology |
|
16 / 30 page ![]() LTC4121/LTC4121-4.2 16 4121fc For more information www.linear.com/LTC4121 protection has been engaged) a DC current, ILOWBAT, is applied to the BAT pin from the INTVCC supply. When the battery voltage rises above VLOWBAT, the switching regulator is enabled and charges the battery at a trickle charge level of 10% of the full scale charge current (in addition to the DC ILOWBAT current). Trickle charging of the battery continues until the sensed battery voltage rises above the trickle charge threshold, VTRKL, or VTRKL_42. When the battery rises above the trickle charge threshold the full scale charge current is applied and the DC trickle charge current is turned off. If the battery remains below the trickle charge threshold for more than 30 minutes, charging terminates and the fault status pin is asserted to indicate a bad battery. After a bad battery fault, the LTC4121 automatically restarts a new charge cycle once the failed battery is removed and replaced with another battery. The LTC4121-4.2 monitors the BATSNS pin volt- age to sense LOWBAT and TRKL conditions. Precision Run/Shutdown Control The LTC4121 remains in a low power disabled mode until the RUN pin is driven above VEN (typically 2.45V). While the LTC4121 is in disabled mode, current drain from the batteryisreducedtoextendbatterylifetime,thestatuspins are both de-asserted, and the FBG pin is high impedance. Charging can be stopped at any time by pulling the RUN pin below 2.25V. The LTC4121 also offers an extremely low operating current shutdown mode when the RUN pin is pulled below VSD(typicallyabout0.7V).Inthiscondition less than 20µA is pulled from the supply at IN. Tie the RUN pin to a resistive divider from the IN supply to program the voltage where the LTC4121 turns on. Examples are shown in Figures 9 and 10. Differential Under Voltage Lockout The LTC4121 monitors the difference between the battery voltage, VBAT, and the input supply voltage, VIN. If the difference (VIN – VBAT) falls to ∆VDUVLO, all functions are disabled and the part is forced into shutdown mode until (VIN – VBAT) rises above the ∆VDUVLO rising threshold. The LTC4121-4.2 monitors the VBATSNS and VIN pin voltages to sense DUVLO condition. OPERATION User Selectable Switching Regulator Operating Frequency The LTC4121 uses a constant-frequency synchronous step-down switching regulator architecture to pro- duce high operating efficiency. The nominal operating frequency, fOSC,isprogrammedbypullingtheFREQpinto either INTVCC or to GND to obtain a switching frequency of 1.5MHz or 750kHz, respectively. The high operating frequency allows the use of smaller external components. Selection of the operating frequency is a trade-off between efficiency,componentsize,andmarginfromtheminimum on-time of the switcher. Operation at lower frequency improves efficiency by reducing internal gate charge and switching losses, but requires larger inductance values to maintain low output ripple. Operation at higher frequency allows the use of smaller components, but may require sufficient margin from the minimum on-time at the lowest duty cycle if fixed-frequency switching is required. PWM Dropout Detector If the input voltage approaches the battery voltage, the LTC4121mayrequiredutycyclesapproaching100%. This mode of operation is known as dropout. In dropout, the operating frequency may fall well below the programmed fOSC value. If the top switch remains on for eight clock cycles, the dropout detector activates and forces the bottom switch on for the remainder of that clock cycle or until the inductor current decays to zero. This avoids a potential source of audible noise when using ceramic input or output capacitors and prevents the boost sup- ply capacitor for the top gate drive from discharging. In dropout operation, the actual charge current may not be able to reach the full-scale programmed value. In such a scenario the analog charge current monitor function does not represent actual charge current being delivered. Burst Mode® Operation At low charge currents, for example during constant- voltage mode, the LTC4121 automatically enters Burst Mode operation. In Burst Mode operation the switcher is periodically forced into standby mode in order to improve |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |