13 / 20 page ![]() LTC1955 13 sn1955 1955fs Electrical Fault Detection Several types of faults are detected by the LTC1955. They include VCCA/VCCB undervoltage, VCCA/VCCB overcurrent, CLK A/CLK B, RST A/RST B, C8A, C4A short circuit, card removal during a transaction, failed answer to reset (ATR), supply undervoltage or UNDERV and chip overtemperature. To prevent false errors from plaguing the microcontroller, the electrical faults are acted upon only after a 5 µs (min) timeout period. Card removal during transaction faults initiate the deactivation sequence immediately. VCCA/VCCB under voltage faults are determined by com- paring the actual output voltage with the internal reference voltage. If the output is more than ~5% below its set point for the entire timeout period, the fault is reported and the deactivation sequence is initiated. VCCA/VCCB overcurrent faults are detected by comparing the output current of the LDOs with an internal reference level. If the current of an LDO is more than 100mA (typ) for the entire timeout period, the fault is reported and the deactivation sequence is initiated. CLK A/CLK B and RST A/RST B faults are detected by comparing the outputs of these pins with their expected signals. If the signal on a pin is incorrect for the entire timeout period, the fault is reported and the deactivation sequence is initiated. The clock channels are a special case. Since they can have a free running clock, the error indication is accumulated over a longer period of time without being cleared. Even though the clock may be running, an error will still be detected. An overtemperature fault is detected by sensing the junc- tion temperature of the IC. If the junction temperature exceeds approximately 150 °C for the entire timeout period, the fault is reported by setting both fault bits (D4 and D12) and the deactivation sequence is initiated. A card removal fault is determined as soon as the PRES A/ PRES B pin is high (for NC/NO = 0). Once this occurs the fault is reported and the deactivation sequence is initiated. If no card is present, and the application software attempts to power up a card socket, an automatic fault will result on that channel. OPERATIO Short circuits on the I/O A/I/O B lines will not be detected by the fault detection hardware; however, a short circuit from these lines to their respective VCCA/VCCB pins will be compliant with the maximum current limits set by appli- cable standards (<15mA). Answer to Reset (ATR) Fault Detection Answer to Reset faults are detected by an internal counter that is started once the RST A/B line goes high. If the DATA pin remains high for 40,000 clock cycles, the ATR fault bit for a given channel is set in the serial port’s status register (see Table 1) and the FAULT pin is brought low. An ATR fault can not occur if the clock mode of a channel is set to synchronous. ATR faults will only occur for asynchronous smart cards. ATR faults are cleared by bringing the RST A/B pin low for the faulted channel. This will also clear the FAULT pin to the Hi-Z state (assuming no other errors are causing FAULT to be low). An ATR fault will not automatically deactivate a card channel. It is the application programmer’s responsibility to check the status register for ATR faults and deactivate the smart card channel in accordance with smart card standards. Generally the application has 50ms (EMV 2.1.3.1, 2.1.3.2) from the 40,000th clock pulse to deacti- vate the card. Once the LTC1955 receives the deactivation command, it will shut down a card channel in less than 250 µs. Using the FAULT Pin The FAULT pin can be used as an interrupt to a microcontroller. It is an open-drain output and generally requires a pull-up resistor. The FAULT pin will go low when either an electrical fault or an answer to reset fault occurs on either channel. Thus there are four possible faults that can cause it to indicate a problem. The serial port’s status register must be polled to find out what type of fault occured and on which channel. The FAULT pin is logically equivalent to D4+D5+D12+D13 (see Table 1). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |