Back Button X9421 Datasheet HTML 3Page - Renesas Technology Corp X9421 Datasheet HTML 4Page - Renesas Technology Corp X9421 Datasheet HTML 5Page - Renesas Technology Corp X9421 Datasheet HTML 6Page - Renesas Technology Corp X9421 Datasheet HTML 7Page - Renesas Technology Corp X9421 Datasheet HTML 8Page - Renesas Technology Corp X9421 Datasheet HTML 9Page - Renesas Technology Corp X9421 Datasheet HTML 10Page - Renesas Technology Corp X9421 Datasheet HTML 11Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 20 page
background image
X9421
FN8196 Rev.1.00
Page 7 of 20
January 14, 2009
Two of the eight instructions are two bytes in length and end
with the transmission of the instruction byte. These instructions
are:
• XFR Data Register to Wiper Counter Register —This
instruction transfers the contents of one specified Data
Register to the Wiper Counter Register.
• XFR Wiper Counter Register to Data Register—This
instruction transfers the contents of the Wiper Counter
Register to the specified associated Data Register.
The basic sequence of the two byte instructions is illustrated in
Figure 4. These two-byte instructions exchange data between
the WCR and one of the Data Registers. A transfer from a Data
Register to a WCR is essentially a write to a static RAM, with the
static RAM controlling the wiper position. The response of the
wiper to this action will be delayed by tWRL. A transfer from the
WCR (current wiper position), to a Data Register is a write to
nonvolatile memory and takes a minimum of tWR to complete.
The transfer can occur between the potentiometer and one of its
associated registers.
Five instructions require a three-byte sequence to complete.
These instructions transfer data between the host and the
X9421; either between the host and one of the Data Registers
or directly between the host and the WCR. These instructions
are:
• Read Wiper Counter Register—read the current wiper
position of the pot,
• Write Wiper Counter Register—change current wiper
position of the pot,
• Read Data Register—read the contents of the selected data
register;
• Write Data Register—write a new value to the selected data
register.
• Read Status—This command returns the contents of the
WIP bit which indicates if the internal write cycle is in
progress.
The sequence of these operations is shown in Figure 5 and
Figure 6.
The final command is Increment/Decrement. It is different from
the other commands, because it’s length is indeterminate.
Once the command is issued, the master can clock the wiper
up and/or down in one resistor segment step; thereby,
providing a fine tuning capability to the host. For each SCK
clock pulse (tHIGH) while SI is HIGH, the selected wiper will
move one resistor segment towards the VH/RH terminal.
Similarly, for each SCK clock pulse while SI is LOW, the
selected wiper will move one resistor segment towards
the VL/RL terminal. A detailed illustration of the sequence and
timing for this operation are shown in Figure 7 and 8.
0101
110A0
I3
I2
I1
I0
R1
R0
0
0
SCK
SI
CS
FIGURE 4. TWO-BYTE INSTRUCTION SEQUENCE
0
101
0A0
I3
I2
I1
I0
R1 R0
0
0
SCL
SI
0
0
D5 D4
D3 D2
D1 D0
CS
11
FIGURE 5. THREE-BYTE INSTRUCTION SEQUENCE (WRITE)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com