Back Button GC3011 Datasheet HTML 7Page - Texas Instruments GC3011 Datasheet HTML 8Page - Texas Instruments GC3011 Datasheet HTML 9Page - Texas Instruments GC3011 Datasheet HTML 10Page - Texas Instruments GC3011 Datasheet HTML 11Page - Texas Instruments GC3011 Datasheet HTML 12Page - Texas Instruments GC3011 Datasheet HTML 13Page - Texas Instruments GC3011 Datasheet HTML 14Page - Texas Instruments GC3011 Datasheet HTML 15Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 33 page
background image
GRAYCHIP,INC.
- 11 -
JULY 22, 1996
GC3011 DIGITAL RESAMPLER
This document contains information which may be changed at any time without notice
The PLL uses a third order loop to reduce jitter due to voltage across R while the pump current is
active. The third order loop is accomplished using a second capacitor C2, which should be significantly
smaller than C1. Generally, C2 = C1 / 100
Suggested values for R, C1 and C2 are shown in Table 1:
2.8.5
External Output Clock Mode
The FIFO output can be clocked using an externally provided clock. Samples will be output from
the chip synchronous to the rising edge of this clock. This mode is used when the user has an external
output clock, or when multiple chips are being synchronized to an output clock generated by one of a bank
of resampler chips. In this mode the OCK clock pin is driven by the external clock.
2.9
POWER DOWN MODES
The chip has a power down and keep alive circuit. This circuit contains a slow, nominally 1 KHz,
oscillator and a clock-loss detect cell. This circuit is used to detect the loss of clock and provide a slow
keep-alive clock to the chip. The circuit is also used to power down the chip by switching from the high speed
input clock to the low speed keep-alive clock. The low speed clock rate is slow enough to power down the
chip while fast enough to refresh the dynamic nodes within the chip. The user can select whether this circuit
is in the automatic clock-loss detect mode, is always on (power down mode), or is disabled (the slow clock
never kicks in).
Table 1: Suggested PLL Filter Components
FOUT
(MHZ)
Loop BW
(% of FOUT)
R
(Ohms)
C1
(
µF)
C2
(
µF)
1
1
125
3.0
0.03
10
1250
0.03
0.0003
10
1
125
0.3
0.003
10
1250
0.003
0.00003
20
1
125
0.2
0.002
10
1250
0.002
0.00002
40
1
125
0.08
0.0008
10
1250
0.0008
0.000008
60
1
125
0.05
0.0005
10
1250
0.0005
0.000005



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com