| Electronic Components Datasheet Search |
|
SMD1102 Datasheet(PDF) 6 Page - Summit Microelectronics, Inc. |
|
|
|||||||||||||||||||||||||||||
SMD1102 Datasheet(HTML) 6 Page - Summit Microelectronics, Inc. |
|
6 / 14 page ![]() 6 SMD1102 / 1103 / 1113 2033 8.1 10/04/01 SUMMIT MICROELECTRONICS, Inc. Single Channel Conversions This command sequence is composed of: the Device Type Identifier, followed by the E/C bit set to zero, then the channel select bits set to the desired value, and the R/M bit set to logic one. After the R/M bit is clocked in the host releases the SDA line and monitors the SDA line for an acknowledge bit (ACK) from the SMD1102/1103/1113. The device will drive the SDA line low indicating it received the command and that it has initiated the acquisition and conversion on the selected channel. The clock source for the acquisition and conversion is an internal clock. After the ACK the SMD1102/1103/1113 will output four dummy zeros on SDA followed by an echo of the channel’s 2 address bits. The remaining bits in this first byte are the two MSBs of the conversion. Refer to Figure 2 for a detailed illustration of this sequence, and for that of retrieving the remaining conversion byte. The host can issue a stop condition after retrieving the conversion data and place the SMD1102/1103/1113 in a low power standby mode. Successive Single Channel Conversions If the host does not issue a stop command after receiving the last bit of the previous conversion, but instead issues an ACK and continues clocking, then the SMD1102/1103/ 1113 will begin another acquisition and conversion pro- cess on the same channel. Auto-Increment In the auto-increment mode, the DAS starts a conversion and then automatically advances to the next channel. The auto-increment mode always starts at channel 0 and switches the channel input in the sequence 0, 1, 2, 0, 1, 2, etc. after each successive conversion. The SMD1102, SMD1103, and SMD1113 independently repeat this pro- cess so long as the host continues clocking the device, supplies ACK bits at the appropriate clock interval, and issues no stop conditions. Refer to Figure 4 for a detailed illustration of the sequence. Programming the Limit Registers Programming the nonvolatile limit registers of the SMD1102/1103/1113 for use with the auto-monitor func- tion is straightforward. Associated with each channel is an 11-bit lower limit register and an 11-bit upper limit register. Ten bits correspond to the 10-bit data, and the MSB represents the monitor option bit. The monitor option bits of the upper and lower limit combine to define the alert region for each channel (described more fully in the section labeled Alert Conditions). Each limit register must be programmed separately with a three byte com- mand sequence. To program the limit register the host first issues a start condition, followed by the device type identifier, the EEPROM/Conversion (E/C) bit (set to one), the channel select bits, and the Read/Monitor bit (set to zero). The second byte consists of four zeroes followed by the limit select bit (zero = lower limit, one = upper limit), the monitor option bit, and the two most significant bits of the limit data. The third byte consists of the remaining eight bits of limit data. After receiving a stop condition, the SMD1102/1103/1113 initiates its internal program sequence. Refer to Figure 5 for details. Six such sequences are required to set the upper and lower limits for all three channels. However, once programmed the data remains stored in EEPROM until reprogrammed. For example, when a device has both VDD and VREF at 5.00V, and an alert must be generated if the voltage on any channel is ≤2.00V or >3.00V, then the monitor option bits are set to 10BIN, the upper limit is set to 266HEX, and the lower limit is set to 199HEX. Reading the Limit Registers The timing diagram for reading the limit register data of a particular channel is shown in Figure 6. The five byte sequence commences with a start condition, followed by the device type identifier, the EEPROM/Conversion bit (set to one), the channel select bits, and the Read/Monitor bit (set to one). After acknowledging the slave byte the device outputs a one, followed by an echo of the channel select bits, a zero, another zero (representing the lower limit data), the monitor option bit and the two most significant bits of the limit data. The third byte consists of the remaining eight bits of the lower limit data. The fourth byte of the output sequence is the same as the second byte except the fifth bit is a one (to indicate upper 2033 Table01C Table 1C. Address Byte — Read/Monitor * Denotes SMD 1102 & SMD1103. Ax bits are for the SMD1113. 7 B D6 B D5 B D4 B D0 B D n o i t c n u F r e i f i t n e d I e p y T e c i v e DM / R 2 A r o * 1 1 A r o * 0 0 A r o * 0 1 0 r o t i n o m - o t u a e l b a n E M O R P E E e t i r w r o C / E ( r e t s i g e r t i m il ) e t a t s 1 - n o c D / A d a e R M O R P E E r o n o i s r e v C / E ( r e t s i g e r t i m il ) e t a t s |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |